Hager

Circuit Breakers

CATEGORIES

Viewing 121 - 140 of 235 products
Compare selected 0/8
View as:
Price
(Price shown excludes VAT)
Description
Product Details
  • R 10,345.82Each
Hager MCCB 3P 40A, Breaking Capacity 25 kA, DIN Rail Mount
  • SeriesHHA
  • Number of Poles3
  • Current Rating40A
  • Breaking Capacity at Maximum Voltage Rating25 kA
  • Rated AC Voltage220/415V
See similar products in MCCBs
  • R 3,045.88Each
Hager NEN MCB, 2P, 6A Curve B, 240 → 400V AC, 10 kA Breaking Capacity
  • Number of Poles2P
  • Current Rating6 A
  • Tripping CharacteristicsType B
  • Rated AC Voltage240 → 400V
  • Breaking Capacity at Maximum Voltage Rating10 kA
See similar products in MCBs
  • R 6,124.67Each
Hager CDH RCD Switch, 40A, 1 Pole, 30mA, Type A-HI, 230V
  • Current Rating40A
  • Number of Poles1
  • Trip Sensitivity30mA
  • Tripping CharacteristicsType A-HI
  • Voltage Rating230V
See similar products in RCCBs
  • R 6,991.29Each
Hager RCD, 25A, 3 Pole, 30mA
  • Circuit Breaker TypeRCD
  • Current Rating25A
  • Number of Poles3
  • Trip Sensitivity30mA
See similar products in RCCBs
  • R 2,896.91Each
Hager CDS RCD Switch, 40A, 2 Pole, 30mA, Type A, 230V
  • Current Rating40A
  • Number of Poles2
  • Trip Sensitivity30mA
  • Tripping CharacteristicsType A
  • Voltage Rating230V
See similar products in RCCBs
  • R 2,713.36Each
Hager NGN MCB, 2P, 32A Curve D, 230 → 400V AC, 6 kA Breaking Capacity
  • Number of Poles2P
  • Current Rating32 A
  • Tripping CharacteristicsType D
  • Rated AC Voltage230 → 400V
  • Breaking Capacity at Maximum Voltage Rating6 kA
See similar products in MCBs
  • R 2,752.68Each
Hager NGN MCB, 2P, 6A Curve D, 230 → 400V AC, 6 kA Breaking Capacity
  • Number of Poles2P
  • Current Rating6 A
  • Tripping CharacteristicsType D
  • Rated AC Voltage230 → 400V
  • Breaking Capacity at Maximum Voltage Rating6 kA
See similar products in MCBs
  • R 489.83Each
Hager 2 Phase Busbar
  • Electrical Phase2
  • SeriesKB
  • Current Rating63A
See similar products in Busbars
  • R 7,877.28Each
Hager NFN MCB, 4P, 50A Curve C, 240 → 400V AC, 10 kA Breaking Capacity
  • Number of Poles4P
  • Current Rating50 A
  • Tripping CharacteristicsType C
  • Rated AC Voltage240 → 400V
  • Breaking Capacity at Maximum Voltage Rating10 kA
See similar products in MCBs
  • R 4,740.96Each
Hager NEN MCB, 2P, 63A Curve B, 240 → 400V AC, 10 kA Breaking Capacity
  • Number of Poles2P
  • Current Rating63 A
  • Tripping CharacteristicsType B
  • Rated AC Voltage240 → 400V
  • Breaking Capacity at Maximum Voltage Rating10 kA
See similar products in MCBs
  • R 143.494
    Each (In a Pack of 10)
  • R 585.26Each
Hager Busbar
  • Current Rating63A
  • SeriesSanVis
See similar products in Busbars
  • R 14,796.15Each
Hager Consumer Unit, IP55 FM
  • SeriesFM
  • RangeQuadro 5
  • Dimensions700 x 260 x 660mm
  • International Protection RatingIP55
  • Length700mm
See similar products in Consumer Units
  • R 3,122.62Each
Hager NGN MCB, 2P, 3A Curve D, 230 → 400V AC, 6 kA Breaking Capacity
  • Number of Poles2P
  • Current Rating3 A
  • Tripping CharacteristicsType D
  • Rated AC Voltage230 → 400V
  • Breaking Capacity at Maximum Voltage Rating6 kA
See similar products in MCBs
  • R 3,677.43Each
Hager NGT MCB, 3P, 16A, 415V AC, 10 kA Breaking Capacity
  • Number of Poles3P
  • Current Rating16 A
  • Rated AC Voltage415V
  • Breaking Capacity at Maximum Voltage Rating10 kA
  • SeriesNGT
See similar products in MCBs
  • R 3,496.56Each
Hager NEN MCB, 2P, 40A Curve B, 240 → 400V AC, 10 kA Breaking Capacity
  • Number of Poles2P
  • Current Rating40 A
  • Tripping CharacteristicsType B
  • Rated AC Voltage240 → 400V
  • Breaking Capacity at Maximum Voltage Rating10 kA
See similar products in MCBs
  • R 5,232.49Each
Hager RCBO, 16A Current Rating, 1P Poles, Type C
  • Current Rating16A
  • Number of Poles1
  • Tripping CharacteristicsType C
  • Circuit Breaker TypeRCBO
  • SeriesADC
See similar products in RCBOs
  • R 6,300.09Each
Hager BFC RCD, 40A, 4 Pole, 300mA, Type AC
  • Circuit Breaker TypeRCD
  • Current Rating40A
  • Number of Poles4
  • Trip Sensitivity300mA
  • Tripping CharacteristicsType AC
See similar products in RCCBs
  • R 10,767.29Each
Hager RCBO, 32A Current Rating, 3P Poles, 30mA Trip Sensitivity, Type AC
  • Current Rating32A
  • Number of Poles3
  • Trip Sensitivity30mA
  • Tripping CharacteristicsType AC
  • SeriesADC
See similar products in RCBOs
  • R 4,275.05Each
Hager NGN MCB, 2P, 50A Curve D, 230 → 400V AC, 6 kA Breaking Capacity
  • Number of Poles2P
  • Current Rating50 A
  • Tripping CharacteristicsType D
  • Rated AC Voltage230 → 400V
  • Breaking Capacity at Maximum Voltage Rating6 kA
See similar products in MCBs
Recently Searched
Frequently Asked Questions
Need help?
Call our Customer Services team on:
+27(0)11 6919300