Fluke 375 FC Clamp Meter, 600 A 600 A ac 1000 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- RS stock no.:
- 905-5917
- Distrelec Article No.:
- 300-37-362
- Mfr. Part No.:
- FLUKE-375 FC
- Manufacturer:
- Fluke
Image representative of range
Subtotal (1 unit)*
R 16 390,00
(exc. VAT)
R 18 848,50
(inc. VAT)
FREE delivery for orders over R 1,500.00
- Plus 1 unit(s) shipping from 04 May 2026
Units | Per unit |
|---|---|
| 1 + | R 16,390.00 |
*price indicative
- RS stock no.:
- 905-5917
- Distrelec Article No.:
- 300-37-362
- Mfr. Part No.:
- FLUKE-375 FC
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Clamp Meter | |
| Maximum DC Current Measurement | 600A | |
| Resistance Resolution | 10Ω | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 1000V dc | |
| Maximum Resistance Measurement | 60kΩ | |
| Model Number | 375 FC | |
| AC Voltage Resolution | 100mV ac | |
| DC Current Accuracy | ±2 % rdg + 5 Digits | |
| Resistance Measurement Accuracy | ±1 % rdg + 5 Digits | |
| Maximum Jaw Opening | 34mm | |
| Minimum Operating Temperature | -10°C | |
| AC Voltage Accuracy | ±1.5 % rdg + 5 Digits | |
| DC Current Resolution | 100mA | |
| DC Voltage Resolution | 100 mV dc | |
| AC Current Accuracy | ±2 % rdg + 5 Digits | |
| AC Current Resolution | 100mA | |
| Clamp Meter Type | AC/DC Clamp Meter | |
| DC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| Maximum Operating Temperature | 50°C | |
| Weight | 395g | |
| Standards/Approvals | IEC 61010-1IEC 61010-2-032IEC 61010-2-033IEC 60529: IP30FCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11 | |
| Width | 85mm | |
| Length | 249mm | |
| Height | 45mm | |
| True RMS | Yes | |
| Functions Measured | DC Current, Temperature, AC Current, AC Voltage, Resistance, DC Voltage | |
| Display Type | LCD Backlight | |
| Battery Type | AA IEC LR06 | |
| Safety Category Level | CAT III, CAT IV | |
| Power Source | Battery | |
| Non-Contact Voltage Detector | Yes | |
| Safety Category Voltage | 1000, 600V | |
| Maximum AC Current Measurement | 600A ac | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Clamp Meter | ||
Maximum DC Current Measurement 600A | ||
Resistance Resolution 10Ω | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 1000V dc | ||
Maximum Resistance Measurement 60kΩ | ||
Model Number 375 FC | ||
AC Voltage Resolution 100mV ac | ||
DC Current Accuracy ±2 % rdg + 5 Digits | ||
Resistance Measurement Accuracy ±1 % rdg + 5 Digits | ||
Maximum Jaw Opening 34mm | ||
Minimum Operating Temperature -10°C | ||
AC Voltage Accuracy ±1.5 % rdg + 5 Digits | ||
DC Current Resolution 100mA | ||
DC Voltage Resolution 100 mV dc | ||
AC Current Accuracy ±2 % rdg + 5 Digits | ||
AC Current Resolution 100mA | ||
Clamp Meter Type AC/DC Clamp Meter | ||
DC Voltage Accuracy ±1 % rdg + 5 Digits | ||
Maximum Operating Temperature 50°C | ||
Weight 395g | ||
Standards/Approvals IEC 61010-1IEC 61010-2-032IEC 61010-2-033IEC 60529: IP30FCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11 | ||
Width 85mm | ||
Length 249mm | ||
Height 45mm | ||
True RMS Yes | ||
Functions Measured DC Current, Temperature, AC Current, AC Voltage, Resistance, DC Voltage | ||
Display Type LCD Backlight | ||
Battery Type AA IEC LR06 | ||
Safety Category Level CAT III, CAT IV | ||
Power Source Battery | ||
Non-Contact Voltage Detector Yes | ||
Safety Category Voltage 1000, 600V | ||
Maximum AC Current Measurement 600A ac | ||
Exempt
Fluke Clamp Meter, 600A Maximum AC Current, 1000V Maximum DC Voltage - FLUKE-375 FC
Features & Benefits
• 2500 A measurement capability when used with flexible probe for large conductors
• True RMS acquisition for accurate readings on non-linear loads
• Bluetooth connectivity to transmit readings wirelessly to devices
• VFD low-pass filter to obtain correct motor-drive measurements
• Resistance to 60 kΩ and temperature input for multi-parameter troubleshooting
**Applications**
• Ideal for preventative maintenance and trending of intermittent faults
• Used for site voltage verification and non-contact live detection
• Can be used with logging software for asset condition records
• Suitable for large-current measurement on busbars with flexible probe
What power source and operating temperatures does it support?
How does the instrument handle high-energy work environments?
What measurement accuracy and resolution are provided for current and voltage?
How are intermittent events recorded and reviewed?
What ingress protection and weight considerations affect field use?
Related links
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 376 Clamp Meter CAT IV Non-Contact Voltage Detector
- FLIR CM275 Clamp Meter CAT IV Non-Contact Voltage Detector
- FLIR VT8 Clamp Meter CAT IV Non-Contact Voltage Detector
- RS PRO 156B Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 375 Clamp Meter 600 V dc CAT III, CAT IV
- Fluke 378 FC Clamp Meter CAT IV 600 V Non-Contact Voltage