FLIR VT8 Clamp Meter, 200 A 200 A 1000 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- RS stock no.:
- 181-2426
- Distrelec Article No.:
- 301-25-653
- Mfr. Part No.:
- VT8-600
- Manufacturer:
- FLIR
Image representative of range
- RS stock no.:
- 181-2426
- Distrelec Article No.:
- 301-25-653
- Mfr. Part No.:
- VT8-600
- Manufacturer:
- FLIR
Select all | Attribute | Value |
|---|---|---|
| Brand | FLIR | |
| Product Type | Clamp Meter | |
| Maximum DC Current Measurement | 200A | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 1000V dc | |
| Maximum Resistance Measurement | 60MΩ | |
| Model Number | VT8 | |
| Resistance Measurement Accuracy | ±1.5 % | |
| Minimum Operating Temperature | 10°C | |
| AC Voltage Accuracy | ±1 % | |
| AC Voltage Resolution | 100mV ac | |
| Maximum Jaw Opening | 15.5mm | |
| DC Voltage Accuracy | ±1 % | |
| Clamp Meter Type | AC-DC Open Jaw Clamp Meter | |
| AC Current Resolution | 100mA | |
| DC Voltage Resolution | 100 mV dc | |
| AC Current Accuracy | ±2.5 % | |
| DC Current Accuracy | ±2.5 % | |
| DC Current Resolution | 100mA | |
| Maximum Operating Temperature | 50°C | |
| Height | 53mm | |
| Weight | 163.7g | |
| Standards/Approvals | No | |
| Width | 35mm | |
| Length | 210mm | |
| True RMS | Yes | |
| Functions Measured | AC Current, AC Voltage, Auto Ranging, Capacitance, Continuity, Data Hold, DC Current, DC Voltage, NCV (Non-contact Voltage), Relative Mode, Resistance, True RMS | |
| Display Type | LCD | |
| Battery Type | AA | |
| Safety Category Voltage | 600V | |
| Safety Category Level | CAT III, CAT IV | |
| Power Source | Battery | |
| Non-Contact Voltage Detector | Yes | |
| Maximum Temperature Measurement | 60°C | |
| Maximum AC Current Measurement | 200A | |
| Select all | ||
|---|---|---|
Brand FLIR | ||
Product Type Clamp Meter | ||
Maximum DC Current Measurement 200A | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 1000V dc | ||
Maximum Resistance Measurement 60MΩ | ||
Model Number VT8 | ||
Resistance Measurement Accuracy ±1.5 % | ||
Minimum Operating Temperature 10°C | ||
AC Voltage Accuracy ±1 % | ||
AC Voltage Resolution 100mV ac | ||
Maximum Jaw Opening 15.5mm | ||
DC Voltage Accuracy ±1 % | ||
Clamp Meter Type AC-DC Open Jaw Clamp Meter | ||
AC Current Resolution 100mA | ||
DC Voltage Resolution 100 mV dc | ||
AC Current Accuracy ±2.5 % | ||
DC Current Accuracy ±2.5 % | ||
DC Current Resolution 100mA | ||
Maximum Operating Temperature 50°C | ||
Height 53mm | ||
Weight 163.7g | ||
Standards/Approvals No | ||
Width 35mm | ||
Length 210mm | ||
True RMS Yes | ||
Functions Measured AC Current, AC Voltage, Auto Ranging, Capacitance, Continuity, Data Hold, DC Current, DC Voltage, NCV (Non-contact Voltage), Relative Mode, Resistance, True RMS | ||
Display Type LCD | ||
Battery Type AA | ||
Safety Category Voltage 600V | ||
Safety Category Level CAT III, CAT IV | ||
Power Source Battery | ||
Non-Contact Voltage Detector Yes | ||
Maximum Temperature Measurement 60°C | ||
Maximum AC Current Measurement 200A | ||
- COO (Country of Origin):
- CN
FLIR Clamp metre, AC-DC, True RMS - VT8-600
Features & Benefits
Applications
Can it measure both AC and DC voltage and current accurately?
Will it help me detect live AC voltages without contact?
Is it suitable for professionals working in the automation industry?
Related links
- FLIR VT8 Clamp Meter CAT IV Non-Contact Voltage Detector
- FLIR CM275 Clamp Meter CAT IV Non-Contact Voltage Detector
- Metrix MX670 Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 376 Clamp Meter CAT IV Non-Contact Voltage Detector
- RS PRO 156B Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector