LEM DVC Series Current Transducer 20 mA 24 V
- RS stock no.:
- 106-786
- Distrelec Article No.:
- 301-86-167
- Mfr. Part No.:
- DVC 1000
- Manufacturer:
- LEM
Subtotal (1 unit)*
R 2 808,10
(exc. VAT)
R 3 229,32
(inc. VAT)
FREE delivery for orders over R 1,500.00
In Stock
- 21 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | R 2,808.10 |
*price indicative
- RS stock no.:
- 106-786
- Distrelec Article No.:
- 301-86-167
- Mfr. Part No.:
- DVC 1000
- Manufacturer:
- LEM
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | LEM | |
| Product Type | Current Transducer | |
| Series | DVC | |
| Secondary Current | 30 mA | |
| Primary Current | 20mA | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 85°C | |
| Weight | 57g | |
| Standards/Approvals | EN 50155: 2021, IEC 61000-6-4: 2016, IEC 61010-1: 2010, IEC 61800-3: 2005, UL 508, IEC 62497-1: 2010, IEC 62109-1: 2010, IEC 61800-5-1: 2007, UL 508: 2018, CSA C22.2 No. 14-18, EN 50121-3-2: 2016, IEC 61000-6-2: 2016 | |
| Maximum Operating Frequency | 35kHz | |
| Supply Voltage | 24 V | |
| Minimum Operating Frequency | 20kHz | |
| Select all | ||
|---|---|---|
Brand LEM | ||
Product Type Current Transducer | ||
Series DVC | ||
Secondary Current 30 mA | ||
Primary Current 20mA | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 85°C | ||
Weight 57g | ||
Standards/Approvals EN 50155: 2021, IEC 61000-6-4: 2016, IEC 61010-1: 2010, IEC 61800-3: 2005, UL 508, IEC 62497-1: 2010, IEC 62109-1: 2010, IEC 61800-5-1: 2007, UL 508: 2018, CSA C22.2 No. 14-18, EN 50121-3-2: 2016, IEC 61000-6-2: 2016 | ||
Maximum Operating Frequency 35kHz | ||
Supply Voltage 24 V | ||
Minimum Operating Frequency 20kHz | ||
Exempt
The LEM Voltage Transducer is used for the electronic measurement of voltage such as DC, AC, pulsed with galvanic separation between the primary and the secondary circuit. It has Very low sensitivity to common mode voltage variations.
Low consumption and low losses
Compact design
Fast delay time
Low temperature drift
Related links
- LEM DVC Series Current Transformer, 4.75 → 5.25 V
- Socomec 192Y Series Current Transducer 20 mA Output, 24 V dc
- Socomec 192Y Series Current Transducer 20 mA Output 230 V ac
- LEM CTSR Series Current Transducer 4 → 20 mA Output
- Siemens 5SV Series Current Transformer 30 mA Output
- LEM AHR Series ASIC Open Loop Hall Effect Current Transducer 4 → 20 mA Output, 20 → 50 V
- LEM AHR Series ASIC Open Loop Hall Effect Current Transducer 4 → 20 mA Output, 20 → 50 V
- Siemens 5SV Series Current Transformer 30 mA Output