Schneider Electric, LRD Thermal Overload Relay 1 NO/1 NC, Trip Dial: 30 → 40 A, 30A, 40 A F.L.C, 40A Contact Rating, 22
- RS stock no.:
- 727-6210
- Mfr. Part No.:
- LRD340
- Manufacturer:
- Schneider Electric
- RS stock no.:
- 727-6210
- Mfr. Part No.:
- LRD340
- Manufacturer:
- Schneider Electric
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| FLC Motor Rating | 30A, 40A | |
| Product Type | Thermal Overload Relay | |
| Relay Contact Current | 40A | |
| Mount Type | Under Contactor Mount | |
| Series | LRD | |
| Power Rating | 22kW | |
| Pole and Throw Configuration | 3 | |
| Terminal Type | Screw | |
| Normal State Configuration | 1 NO/1 NC | |
| IP Rating | IP20 | |
| Reset Method | Push Button | |
| Number of Auxiliary Contacts | 2 | |
| Width | 55mm | |
| Adjustable Current Range | 30 → 40 A | |
| Minimum Operating Temperature | -20°C | |
| Length | 70mm | |
| Contact Voltage | 1kV ac | |
| Maximum Operating Temperature | 60°C | |
| Depth | 116mm | |
| Standards/Approvals | UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, GB/T 14048.5, UL 60947-4-1 | |
| Supply Voltage | 690V | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
FLC Motor Rating 30A, 40A | ||
Product Type Thermal Overload Relay | ||
Relay Contact Current 40A | ||
Mount Type Under Contactor Mount | ||
Series LRD | ||
Power Rating 22kW | ||
Pole and Throw Configuration 3 | ||
Terminal Type Screw | ||
Normal State Configuration 1 NO/1 NC | ||
IP Rating IP20 | ||
Reset Method Push Button | ||
Number of Auxiliary Contacts 2 | ||
Width 55mm | ||
Adjustable Current Range 30 → 40 A | ||
Minimum Operating Temperature -20°C | ||
Length 70mm | ||
Contact Voltage 1kV ac | ||
Maximum Operating Temperature 60°C | ||
Depth 116mm | ||
Standards/Approvals UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, GB/T 14048.5, UL 60947-4-1 | ||
Supply Voltage 690V | ||
- COO (Country of Origin):
- FR
Schneider Electric LRD Series Thermal Overload Relay, 30 to 40 A Motor Rating, Automatic Reset Method - LRD340
Features & Benefits
Applications
What is the significance of the 30 to 40A adjustment range?
How does the automatic reset function work?
Can it be used with different types of networks?
What type of terminals does this device feature?
What is the impact of the rated operational voltage?
Standards
Related links
- Schneider Electric 30A 40A Contact Rating, 18.5 kW 3
- Schneider Electric 23A 32A Contact Rating, 22 kW 3
- Schneider Electric 37A 50A Contact Rating 690V 3
- Schneider Electric 30A 38A Contact Rating, 18.5 kW 3
- Schneider Electric 25A 40A Contact Rating, 22 kW 3
- Siemens 40A F.L.C 22 kW 3P
- Schneider Electric 40A Contact Rating
- Schneider Electric 13A 13A Contact Rating, 5.5 kW 3