Siemens Auxiliary Contact, 2 Contact, 1 NO/1 NC, 3RH2911, Snap-On, 10 A, 17V dc, 3RH2911-1LA11
- RS stock no.:
- 203-2098
- Distrelec Article No.:
- 136-23-054
- Mfr. Part No.:
- 3RH2911-1LA11
- Manufacturer:
- Siemens
Subtotal (1 unit)*
R 217,37
(exc. VAT)
R 249,98
(inc. VAT)
FREE delivery for orders over R 1,500.00
In Stock
- 54 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | R 217.37 |
*price indicative
- RS stock no.:
- 203-2098
- Distrelec Article No.:
- 136-23-054
- Mfr. Part No.:
- 3RH2911-1LA11
- Manufacturer:
- Siemens
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Siemens | |
| Number of Contacts | 2 | |
| Product Type | Auxiliary Contact | |
| Normal State Configuration | 1 NO/1 NC | |
| Series | 3RH2911 | |
| Mount Type | Snap-On | |
| Contact Current | 10A | |
| Terminal Type | Spring Loaded | |
| Pole and Throw Configuration | DPDT | |
| Contact Voltage | 17V dc | |
| Mounting Location | Front Side | |
| Minimum Operating Temperature | -25°C | |
| Rated Insulation Voltage Ui | 690V | |
| Operational Current Ie | 10A | |
| Mechanical Durability | 10Mcycles | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | No | |
| Select all | ||
|---|---|---|
Brand Siemens | ||
Number of Contacts 2 | ||
Product Type Auxiliary Contact | ||
Normal State Configuration 1 NO/1 NC | ||
Series 3RH2911 | ||
Mount Type Snap-On | ||
Contact Current 10A | ||
Terminal Type Spring Loaded | ||
Pole and Throw Configuration DPDT | ||
Contact Voltage 17V dc | ||
Mounting Location Front Side | ||
Minimum Operating Temperature -25°C | ||
Rated Insulation Voltage Ui 690V | ||
Operational Current Ie 10A | ||
Mechanical Durability 10Mcycles | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals No | ||
- COO (Country of Origin):
- CZ
Siemens 3RH2911 Series Auxiliary Switch, DPDT Pole and Throw Configuration, 10A Contact Current - 3RH2911-1LA11
This auxiliary switch snaps onto the front of contactors and relays to provide mirrored signalling and positively driven switching for control circuits. It is designed for use with specified contactor families and offers screw-terminal connections with cable entry from the top. The unit operates across a wide ambient range and meets multiple safety and regional approvals for industrial control applications.
Features and Benefits:
• 1NO1NC contact arrangement delivers distinct signalling paths
• 10A current rating enables switching of moderate control loads
• 690V rated insulation supports higher-voltage AC systems
• -25°C to 60°C operating range suits varied installations
• Mechanical durability 10M cycles ensures long-term operational life
• 10A current rating enables switching of moderate control loads
• 690V rated insulation supports higher-voltage AC systems
• -25°C to 60°C operating range suits varied installations
• Mechanical durability 10M cycles ensures long-term operational life
Applications
• Suitable for mounting on 3RT2 contactors and 3RH2 relays
• Used with control circuits requiring mirror contact functionality
• Ideal for auxiliary signalling in industrial motor control systems
• Can be used where screw-terminal connections are required
• Suitable for installations needing Snap-on front-side mounting
• Used with control circuits requiring mirror contact functionality
• Ideal for auxiliary signalling in industrial motor control systems
• Can be used where screw-terminal connections are required
• Suitable for installations needing Snap-on front-side mounting
What type of electrical connection does it use?
It uses screw-type terminals compatible with solid or stranded conductors up to 2.5 mm².
How does it perform under repeated operation?
Mechanical service life is specified at 10 000 000 operating cycles with electrical endurance up to 200 000 cycles at AC-15, 230 V.
What approvals support its use in certified systems?
It is approved to CCC, cULus, EAC and UKCA standards.
Can it switch DC control voltages reliably?
Contact ratings include DC operation down to 17 Vdc with specified currents across various DC voltage levels.
What short-circuit protection is recommended for the auxiliary circuit?
A 10 A fuse link of type gG with 690 V, 1 kA capability or a 10 A, 0.4 kA characteristic miniature circuit-breaker is specified.
Related links
- Siemens Auxiliary Contact 1 NO/1 NC Snap-On 17V dc, 3RH2911-1MA11
- Siemens Auxiliary Contact 1 NO/3 NC Snap-On 17V dc, 3RH2911-1GA13
- Siemens Auxiliary Contact 2 NC/2 NO Snap-On 17V dc, 3RH2911-2GA22
- Siemens Auxiliary Contact 2 NC/2 NO Snap-On 17V dc, 3RH2911-2XA22-0MA0
- Siemens Auxiliary Contact 4 NO Snap-On 17V dc, 3RH2911-2GA40
- Siemens Auxiliary Contact 1 NO/1 NC Snap-On 60V dc, 3RH2911-1NF11
- Siemens Auxiliary Contact 1 NO/1 NC Snap-On 220V dc, 3RH2911-2DE11
- Siemens Auxiliary Contact 1 NO/1 NC Snap-On 17V dc, 3RH1921-2DE11
