Alpha Wire Pro-Tekt Series Data Cable, 1.23 mm², 50 m, Grey Sheath Polyvinyl Chloride
- RS stock no.:
- 740-4743
- Mfr. Part No.:
- B957064 GE321
- Manufacturer:
- Alpha Wire
Bulk discount available
Subtotal (1 reel of 50 metres)*
R 13 622,45
(exc. VAT)
R 15 665,82
(inc. VAT)
FREE delivery for orders over R 1,500.00
In Stock
- 4 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s) | Per Reel | Per Metre* |
|---|---|---|
| 1 - 14 | R 13,622.45 | R 272.449 |
| 15 + | R 13,281.89 | R 265.638 |
*price indicative
- RS stock no.:
- 740-4743
- Mfr. Part No.:
- B957064 GE321
- Manufacturer:
- Alpha Wire
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Alpha Wire | |
| Product Type | Data Cable | |
| Cross Sectional Area | 1.23mm² | |
| Cable Length | 50m | |
| Jacket Colour | Grey | |
| Outside Diameter | 9.4mm | |
| Conductor Type | Copper | |
| Minimum Operating Temperature | -30°C | |
| Jacket Material | Polyvinyl Chloride | |
| Maximum Operating Temperature | 105°C | |
| Standards/Approvals | CE, CSA Certified, UL | |
| Voltage | 300V | |
| Series | Pro-Tekt | |
| Fire Behaviour | Flame Retardant | |
| Conductor Material | Tin Copper Wire | |
| Core Strands | 7 | |
| Select all | ||
|---|---|---|
Brand Alpha Wire | ||
Product Type Data Cable | ||
Cross Sectional Area 1.23mm² | ||
Cable Length 50m | ||
Jacket Colour Grey | ||
Outside Diameter 9.4mm | ||
Conductor Type Copper | ||
Minimum Operating Temperature -30°C | ||
Jacket Material Polyvinyl Chloride | ||
Maximum Operating Temperature 105°C | ||
Standards/Approvals CE, CSA Certified, UL | ||
Voltage 300V | ||
Series Pro-Tekt | ||
Fire Behaviour Flame Retardant | ||
Conductor Material Tin Copper Wire | ||
Core Strands 7 | ||
Belden Pro-Tekt Series Data Cable, 50m Cable Length, 300V Voltage - B957064 GE321
This data cable provides a reliable connection solution for industrial and commercial communication systems, supplying signal transmission across a 50m length. Constructed for use where flame resistance and robust conductor performance are required, it is suited to environments demanding continuity under a range of temperatures and regulatory approvals.
Features & Benefits
• Tin-plated copper conductor enhances corrosion resistance and conductivity
• Seven-strand conductor construction improves flexibility for routed runs
• 1.23 mm² conductor cross section supports consistent current handling
• Rated for 300V operation to accommodate common control circuits
• Flame-retardant construction reduces fire propagation risk
• Maximum operating temperature 105 °C enables high-temperature installation
• Seven-strand conductor construction improves flexibility for routed runs
• 1.23 mm² conductor cross section supports consistent current handling
• Rated for 300V operation to accommodate common control circuits
• Flame-retardant construction reduces fire propagation risk
• Maximum operating temperature 105 °C enables high-temperature installation
**Applications**
• Suitable for factory automation signal cabling in control panels
• Ideal for wiring between sensors and PLCs in machinery rooms
• Used with distributed I/O modules in production line installations
• Can be used for cabling in electrical enclosures with restricted space
• Suitable for retrofitting industrial communication links in plant upgrades
• Ideal for wiring between sensors and PLCs in machinery rooms
• Used with distributed I/O modules in production line installations
• Can be used for cabling in electrical enclosures with restricted space
• Suitable for retrofitting industrial communication links in plant upgrades
What conductor material is used and why is it beneficial?
The conductors are tin-plated copper which combines the conductivity of copper with a tin coating that improves solderability and offers enhanced resistance to corrosion in humid or chemically Active atmospheres.
What is the cables outer composition and how does it affect installation?
The sheath is MADE from polyvinyl chloride, providing mechanical protection and abrasion resistance while remaining flexible enough for routing through conduits and cable trays.
Which approvals does it hold and what does that imply for system design?
The cable is approved to UL, CE and CSA standards, indicating it meets recognised safety and performance criteria across multiple regulatory regions and can be specified in designs requiring these certifications.
How does the cable perform in low-temperature environments?
It is specified to function down to -30 °C, maintaining flexibility and electrical continuity for installations exposed to sub-zero ambient conditions.
Related links
- Alpha Wire ProTekt Series Data Cable 1.23 mm² 16 AWG Screened Shield
- Alpha Wire ProTekt Series Data Cable 1.23 mm² 16 AWG Screened Shield
- Alpha Wire ProTekt Series Data Cable 0.35 mm² 22 AWG Screened Shield
- Alpha Wire ProTekt Series Data Cable 0.23 mm² 24 AWG Screened Shield
- Alpha Wire ProTekt Series Data Cable 6 Cores Screened 50m, Screened Shield
- Alpha Wire ProTekt Series Data Cable 6 Cores Screened 50m, Screened Shield
- Alpha Wire ProTekt Series Data Cable 6 Cores Screened 50m, Screened Shield
- Alpha Wire ProTekt Series Data Cable 6 Cores Screened 50m, Screened Shield