United Automation FC36M, Thyristor Trigger Module
- RS stock no.:
- 232-9347
- Mfr. Part No.:
- FC36M
- Manufacturer:
- United Automation
Bulk discount available
Subtotal (1 unit)*
R 7 491,63
(exc. VAT)
R 8 615,37
(inc. VAT)
FREE delivery for orders over R 1,500.00
In Stock
- Plus 4 unit(s) shipping from 05 January 2026
- Plus 5 unit(s) shipping from 06 February 2026
- Plus 5 unit(s) shipping from 20 February 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 - 4 | R 7,491.63 |
| 5 + | R 7,304.34 |
*price indicative
- RS stock no.:
- 232-9347
- Mfr. Part No.:
- FC36M
- Manufacturer:
- United Automation
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | United Automation | |
| Output Isolation | 3500Vrms | |
| Input Voltage DC | 5V dc | |
| Dimensions | 162 x 108 x 40mm | |
| Maximum Operating Temperature | +65 °C | |
| Minimum Operating Temperature | 0 °C | |
| Select all | ||
|---|---|---|
Brand United Automation | ||
Output Isolation 3500Vrms | ||
Input Voltage DC 5V dc | ||
Dimensions 162 x 108 x 40mm | ||
Maximum Operating Temperature +65 °C | ||
Minimum Operating Temperature 0 °C | ||
- COO (Country of Origin):
- GB
Phase Angle & Burst Firing Three-Phase, FC36M - A34411 (No DIN housing), 415V
A microprocessor based thyristor firing control PCB with both Phase Angle and Burst Firing options.
Suitable for ac/dc resistive/inductive loads, via thyristor pairs on 3-phase stacks
No external phasing transformers required
Analogue control inputs 0-5Vdc and 4-20mA current loop
Digital isolated control, opto-coupled +5 → +25Vdc
Selectable current limit with LED indication
Over-current latching trip to 150% LED indication
Selectable resistive/inductive loads
Selectable phase reversal
Output status indication
No external phasing transformers required
Analogue control inputs 0-5Vdc and 4-20mA current loop
Digital isolated control, opto-coupled +5 → +25Vdc
Selectable current limit with LED indication
Over-current latching trip to 150% LED indication
Selectable resistive/inductive loads
Selectable phase reversal
Output status indication
The number of complete mains cycles during fixed repeating periods (typically 1 to 10 seconds) is varied, thus altering the duty cycle or on-/off-time ratio. Trigger pulses coincide with the zero-crossing times of the mains supply thus ensuring no RFI is produced when using resistive loads.
Related links
- United Automation AVR-25, Thyristor Trigger Module
- United Automation DMFC12 415VAC, Thyristor Trigger Module
- United Automation AFM11, Thyristor Trigger Module
- United Automation FC11BL, Thyristor Trigger Module
- United Automation MAT, Thyristor Trigger Module
- United Automation STOM-1, Thyristor Trigger Module
- United Automation DMFC36, Thyristor Trigger Module
- United Automation A34462, Thyristor Trigger Module
