Schneider Electric TeSys GB2 Thermal Circuit Breaker - 1-Pole, DIN Rail, 3A Current Rating, 1.5 kA, 110V ac, 48 V dc
- RS stock no.:
- 323-9015
- Mfr. Part No.:
- GB2CD08
- Manufacturer:
- Schneider Electric
Currently unavailable
Sorry, we don't know when this will be back in stock.
- RS stock no.:
- 323-9015
- Mfr. Part No.:
- GB2CD08
- Manufacturer:
- Schneider Electric
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Thermal Circuit Breaker | |
| Current Rating | 3A | |
| Range | TeSys | |
| Number of Poles | 1 | |
| Series | GB2 | |
| Width | 15mm | |
| Mount Type | DIN Rail | |
| Terminal Type | Screw | |
| Tripping Mechanism | Thermal Magnetic | |
| Reset Actuator Type | Toggle Switch | |
| Rated AC Voltage | 110V ac | |
| Height | 80mm | |
| Standards/Approvals | RoHS, CE | |
| Depth | 70mm | |
| Break Time | Medium | |
| Breaking Capacity | 1.5kA | |
| Rated DC Voltage | 48V dc | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Thermal Circuit Breaker | ||
Current Rating 3A | ||
Range TeSys | ||
Number of Poles 1 | ||
Series GB2 | ||
Width 15mm | ||
Mount Type DIN Rail | ||
Terminal Type Screw | ||
Tripping Mechanism Thermal Magnetic | ||
Reset Actuator Type Toggle Switch | ||
Rated AC Voltage 110V ac | ||
Height 80mm | ||
Standards/Approvals RoHS, CE | ||
Depth 70mm | ||
Break Time Medium | ||
Breaking Capacity 1.5kA | ||
Rated DC Voltage 48V dc | ||
Non Compliant
- COO (Country of Origin):
- FR
Schneider Electric GB2 Series Thermal Circuit Breaker, 3A Current, 250/277V Rated AC Voltage - GB2CD08
This thermal circuit breaker is designed to provide overcurrent protection for control and distribution applications in industrial and commercial systems. It operates on thermal‑magnetic trip principles and is intended for DIN‑rail mounting, offering Compact protection suited to AC and DC networks within moderate power circuits.
Features & Benefits
• 3A rated current delivers precise low‑current protection for control circuits
• 3kA breaking capacity limits fault energy at typical supply voltages
• Thermal‑magnetic trip offers both overload and short‑circuit response
• Toggle reset actuator enables Rapid manual reclosure after fault clearing
• Cable Terminal connections accept standard solid and flexible conductors
• 4kV impulse withstand reduces susceptibility to transient overvoltages
• 3kA breaking capacity limits fault energy at typical supply voltages
• Thermal‑magnetic trip offers both overload and short‑circuit response
• Toggle reset actuator enables Rapid manual reclosure after fault clearing
• Cable Terminal connections accept standard solid and flexible conductors
• 4kV impulse withstand reduces susceptibility to transient overvoltages
Applications
• Suitable for protection of control panels and automation modules
• Ideal for branch circuits in building services and machine control
• used with 48V DC control supplies and signalling circuits
• Can be used for AC motor control auxiliaries and pilot circuits
• Ideal for branch circuits in building services and machine control
• used with 48V DC control supplies and signalling circuits
• Can be used for AC motor control auxiliaries and pilot circuits
What mounting options does it provide for panel integration?
It clips directly onto standard DIN rails or can be mounted on a plate using the provided clip system for flexible installation.
Which conductor sizes are supported for reliable termination?
Terminals accept solid conductors from 0.75 to 6mm² and flexible conductors with ferrules up to 4mm² depending on the connection point.
How does it perform under mechanical stress and vibration?
The device meets shock and vibration criteria withstanding 22Gn shocks for 20ms and vibration up to 5Gn across 5 to 110Hz.
What environmental and safety characteristics are relevant for installation?
It has IP20 protection, operates from −20 to 60°C, stores at −40 to 80°C, and uses halogen‑free plastic parts for reduced fire risk.
Standards
IEC947-2
Related links
- Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 500mA Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 10A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 6A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 8A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 5A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 1A Current Rating
- Schneider Electric TeSys Thermal Magnetic Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 2A
- Schneider Electric Thermal Circuit Breaker - GB2 2 Pole 277V ac Voltage Rating DIN Rail Mount, 3A Current Rating