Schneider Electric TeSys TeSyS GB2 Thermal Circuit Breaker - 1-Pole, DIN Rail, 2 A Current Rating, 1.5 kA, 110 V ac, 48
- RS stock no.:
- 312-3645
- Mfr. Part No.:
- GB2CB07
- Manufacturer:
- Schneider Electric
Bulk discount available
Subtotal (1 unit)*
R 647,13
(exc. VAT)
R 744,20
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 - 9 | R 647.13 |
| 10 - 24 | R 630.95 |
| 25 + | R 612.02 |
*price indicative
- RS stock no.:
- 312-3645
- Mfr. Part No.:
- GB2CB07
- Manufacturer:
- Schneider Electric
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Thermal Circuit Breaker | |
| Number of Poles | 1 | |
| Range | TeSys | |
| Series | TeSyS GB2 | |
| Mount Type | DIN Rail | |
| Terminal Type | Screw | |
| Tripping Mechanism | Thermal Magnetic | |
| Reset Actuator Type | Toggle Switch | |
| Height | 80mm | |
| Depth | 70mm | |
| Standards/Approvals | RoHS, CE | |
| Break Time | Medium | |
| Breaking Capacity | 1.5kA | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Thermal Circuit Breaker | ||
Number of Poles 1 | ||
Range TeSys | ||
Series TeSyS GB2 | ||
Mount Type DIN Rail | ||
Terminal Type Screw | ||
Tripping Mechanism Thermal Magnetic | ||
Reset Actuator Type Toggle Switch | ||
Height 80mm | ||
Depth 70mm | ||
Standards/Approvals RoHS, CE | ||
Break Time Medium | ||
Breaking Capacity 1.5kA | ||
Non Compliant
Schneider Electric GB2 Series Thermal Circuit Breaker, 2A Current, 250V Rated AC Voltage - GB2CB07
This thermal circuit breaker is a single-pole protective device designed for control and automation panels where compact, resettable overcurrent protection is required. It combines a thermal trip element with a magnetic short‑circuit response to protect circuits in AC and DC networks while mounting neatly on DIN-rail systems.
Features & Benefits
• 10kA breaking capacity supports high-fault current interruption
• 2A rated current delivers defined protection for low-current circuits
• Thermal-magnetic trip offers both overload and short‑circuit protection
• Toggle reset actuator enables quick manual reclosure after trip
• Cable terminals accept 0.75 to 6mm² conductors for flexible wiring
• 4kV impulse withstand improves immunity to transient overvoltages
• 2A rated current delivers defined protection for low-current circuits
• Thermal-magnetic trip offers both overload and short‑circuit protection
• Toggle reset actuator enables quick manual reclosure after trip
• Cable terminals accept 0.75 to 6mm² conductors for flexible wiring
• 4kV impulse withstand improves immunity to transient overvoltages
Applications
• Suitable for control panels in industrial automation systems
• Ideal for protection of DC control circuits at 48V
• Used with motor starters and contactor control coils
• Can be used for distribution branches in machine electrical cabinets
• Suitable for retrofit installations on 35mm DIN rails
• Ideal for protection of DC control circuits at 48V
• Used with motor starters and contactor control coils
• Can be used for distribution branches in machine electrical cabinets
• Suitable for retrofit installations on 35mm DIN rails
What electrical networks can it be used on?
It is designed for both AC and DC operation, with rated operational voltages of up to 250V AC at 50/60Hz and 48V DC.
How is it mounted and secured in a control cabinet?
It clips onto standard 35mm DIN rail and is compatible with both horisontal and vertical mounting positions.
What are the connection capabilities for field wiring?
The device accepts solid conductors up to 6mm² and flexible conductors with or without ferrules within the specified ranges, secured with 1.2N·m tightening torque.
How does the device perform mechanically and electrically over time?
It is specified for 8,000 mechanical cycles and 8,000 electrical operations to ensure long service life under normal operating conditions.
Standards
IEC947-2
Related links
- Schneider Electric TeSys Thermal Circuit Breaker - GB2 2 Pole 277V ac Voltage Rating DIN Rail Mount, 2A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 Single Pole 277V ac Voltage Rating DIN Rail Mount, 16A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 Single Pole 277V ac Voltage Rating DIN Rail Mount, 20A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 Single Pole 277V ac Voltage Rating DIN Rail Mount, 5A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 Single Pole 277V ac Voltage Rating DIN Rail Mount, 1A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 Single Pole 277V ac Voltage Rating DIN Rail Mount, 6A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 Single Pole 277V ac Voltage Rating DIN Rail Mount, 4A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 Single Pole 277V ac Voltage Rating DIN Rail Mount, 10A Current Rating