Schneider Electric Acti9 iID Series Residual Current Circuit Breaker, 80 A, 4-Pole, 300 mA, Type AC, 1500 A, 220 V dc
- RS stock no.:
- 776-3717
- Mfr. Part No.:
- A9R14480
- Manufacturer:
- Schneider Electric
Image representative of range
Currently unavailable
Sorry, we don't know when this will be back in stock.
- RS stock no.:
- 776-3717
- Mfr. Part No.:
- A9R14480
- Manufacturer:
- Schneider Electric
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 80 A | |
| Number of Poles | 4 | |
| Series | Acti9 iID | |
| Range | Acti9 | |
| Trip Sensitivity | 300mA | |
| Tripping Characteristics | Type AC | |
| Mount Type | DIN Rail | |
| Standards/Approvals | EN/IEC 61008-1, REACH, RoHS | |
| Terminal Type | Screw Clamp | |
| Height | 91mm | |
| Width | 36 mm | |
| Depth | 73.5mm | |
| Breaking Capacity | 1500A | |
| Rated DC Voltage | 220 V dc | |
| Earth Leakage Protection Type | AC | |
| Break Time | Instantaneous | |
| Reset Actuator Type | Toggle Switch | |
| Rated AC Voltage | 415 V ac | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 80 A | ||
Number of Poles 4 | ||
Series Acti9 iID | ||
Range Acti9 | ||
Trip Sensitivity 300mA | ||
Tripping Characteristics Type AC | ||
Mount Type DIN Rail | ||
Standards/Approvals EN/IEC 61008-1, REACH, RoHS | ||
Terminal Type Screw Clamp | ||
Height 91mm | ||
Width 36 mm | ||
Depth 73.5mm | ||
Breaking Capacity 1500A | ||
Rated DC Voltage 220 V dc | ||
Earth Leakage Protection Type AC | ||
Break Time Instantaneous | ||
Reset Actuator Type Toggle Switch | ||
Rated AC Voltage 415 V ac | ||
- COO (Country of Origin):
- ES
RCCB Acti9 iID
The Acti 9 iID DIN rail RCCBs, are fully coordinated with the iC60 MCBs to warranty an absolute people and equipment protection against electrocution, risk of fire and improved continuity of service.
iID residual current circuit breakers AC Type provide:
Protection of persons against electric shock by direct contact (≦ 30 mA).
Protection of persons against electric shock by indirect contact (≧ 100 mA).
Protection of installations against the risk of fire (300 mA or 500 mA).
iID residual current circuit breakers Asi Type provide:
Protection of persons against electric shock by direct contact (≦ 30 mA).
Protection of persons against electric shock by indirect contact (≧ 300 mA).
Protection of installations against the risk of fire (300 mA or 500 mA).
Increased immunity from electrical interference and polluted or corrosive environments.
Related links
- Schneider Electric iID RCCB 4 Pole Type B-SI, 400V ac
- Schneider Electric iID RCCB 4 Pole Type B-SI, 400V ac
- Schneider Electric iID RCCB 4 Pole Type AC, 415V ac
- Schneider Electric iID RCCB 4 Pole, 300mA
- Schneider Electric iID RCCB 4 Pole, 300mA
- Schneider Electric iID RCCB 4 Pole, 300mA
- Schneider Electric iID RCCB 4 Pole Type AC, 415V ac
- Schneider Electric iID RCCB 4 Pole Type B-SI, 400V ac