Siemens SENTRON Series Residual Current Circuit Breaker, 25 A, 4-Pole, 30 mA, Type A, 10 kA 400 V ac
- RS stock no.:
- 211-9639
- Mfr. Part No.:
- 5SV3342-4KK14
- Manufacturer:
- Siemens
Subtotal (1 unit)*
R 16 150,71
(exc. VAT)
R 18 573,32
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 + | R 16,150.71 |
*price indicative
- RS stock no.:
- 211-9639
- Mfr. Part No.:
- 5SV3342-4KK14
- Manufacturer:
- Siemens
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Siemens | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 25 A | |
| Number of Poles | 4 | |
| Range | SENTRON | |
| Series | SENTRON | |
| Trip Sensitivity | 30mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type A | |
| Terminal Type | Screw | |
| Standards/Approvals | EAC, CE, UKCA, VDE | |
| Width | 72 mm | |
| Depth | 70mm | |
| Height | 90mm | |
| Breaking Capacity | 10kA | |
| Earth Leakage Protection Type | Type A | |
| Break Time | Short | |
| Rated AC Voltage | 400 V ac | |
| Tripping Mechanism | Electromagnetic | |
| Reset Actuator Type | Toggle Switch | |
| Select all | ||
|---|---|---|
Brand Siemens | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 25 A | ||
Number of Poles 4 | ||
Range SENTRON | ||
Series SENTRON | ||
Trip Sensitivity 30mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type A | ||
Terminal Type Screw | ||
Standards/Approvals EAC, CE, UKCA, VDE | ||
Width 72 mm | ||
Depth 70mm | ||
Height 90mm | ||
Breaking Capacity 10kA | ||
Earth Leakage Protection Type Type A | ||
Break Time Short | ||
Rated AC Voltage 400 V ac | ||
Tripping Mechanism Electromagnetic | ||
Reset Actuator Type Toggle Switch | ||
- COO (Country of Origin):
- DE
The Siemens Residual current operated circuit breaker has a 4-pole and Type B+. Used for short-time delayed. Operating current is 25 A and residual current 30 mA. Supply voltage is 400 V. The RCD is the residual current device for touch protection. They have an additional converter to detect DC residual currents and are suitable for use in a three-phase system upstream of input current circuits with rectifiers. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.
Protection class IP IP20 if the distribution board is installed, with connected conductors
Silicon- free