Omron G9SE 1 Auxiliary Contacts Safety Relay 24V dc, Dual-Channel 2 Safety Contacts

Unavailable
RS will no longer stock this product.

Alternative

This product is not currently available. Here is our alternative recommendation.

Each

R 3,645.78

(exc. VAT)

R 4,192.65

(inc. VAT)

RS stock no.:
890-3395
Mfr. Part No.:
G9SE-221-T30 DC24
Manufacturer:
Omron
Find similar products by selecting one or more attributes.
Select all

Brand

Omron

Supply Voltage

24V dc

Number of Channels

2

Safety Contacts

2

Function

Time Delay

Auxiliary Contacts

1

Reset Method

Automatic & Manual

Safety Category ISO 13849-1

4

Terminal Type

Screw

Configurable

Yes

Depth

112mm

Series

G9SE

Width

22.5mm

Length

144.5mm

G9SE Compact Safety Relay Model.


• Compact.
• Easy to install.
• Saves mounting space.
• Saves on installation cost.
• Reduced operational cost.
• Push-In Plus terminal block. (front facing)
• Easy wiring. (front)
• Screw-less terminals.
• 15 ms max response time.
• Diagnostic indicators. (LED)
• OFF-delayed safety input models available.
• 17.5 mm and 22.5 mm widths available.
• PNP Transistor output.
• State OFF delay function to PLe.

G9SE-221-T30-DC24 Safety Relay.


• Safety output.
• Instantaneous DPST-NO (normally open).
• OFF-delayed PDST-NO (normally open). (become instantaneous by setting the OFF-delay time to 0 s)
• Auxiliary output 1 x Solid-state.
• Auxiliary output PNP transistor output load current 100 mA DC max.
• Max OFF-delay time 20 s (OFF-delay time can be set in 16 steps)
• 16 Steps OFF-delay time (0/1/4/5/6/7/8/9/10/12/14/16/20/25/30 s)
• Rated voltage 24 V dc.
• Operating voltage range -15% to 10% of rated supply voltage.
• Rated power consumption 4 W max (loads not included).
• Safety output – Contact output
• OFF-delayed safety output 250 V ac, 5 A, 30 V dc, 5 A (resistive load)

Features and Benefits.


• Operating time (OFF to ON state) 100 ms Max. (normal operation)
• Operating time is the time taken for the safety contact to close (after safety inputs and feedback-reset input are turned ON). Bounce time is not included.
• Response time (ON to OFF state) 15 ms max.
• Accuracy OFF-delay time ±10% of set value.
• Input current 5 mA min.
• ON voltage 11 V dc max.
• OFF voltage 5 V dc max.
• OFF current 1 mA max.
• Cable length 100 m max.
• Reset input time 250ms min.
• Contact resistance 100 mΩ
• Mechanical durability 5000000 operations per min.
• Electrical durability 50000 operations min.
• Minimum applicable load 24 V dc, 4 mA.
• Over voltage category IEC/EN60664-1, safety output Class III, the others Class II.
• Protection IP20
• Insulation resistance 100 mΩ.
• Weight 180 g

Applications Include.


• Emergency stop switches.
• Door switches.
• Light curtains.
• Safety monitoring applications.

Related links