Tektronix ADA400A Oscilloscope Module for Use with TDS400 Series, TDS500 Series, TDS5000 Series, TDS600 Series, TDS700
- RS stock no.:
- 349-8214
- Mfr. Part No.:
- ADA400A
- Manufacturer:
- Tektronix
Currently unavailable
Sorry, we don't know when this will be back in stock.
- RS stock no.:
- 349-8214
- Mfr. Part No.:
- ADA400A
- Manufacturer:
- Tektronix
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Tektronix | |
| For Use With | TDS400 Series, TDS500 Series, TDS5000 Series, TDS600 Series, TDS700 Series, TDS7000 Series | |
| Model Number p | ADA400A | |
| Select all | ||
|---|---|---|
Brand Tektronix | ||
For Use With TDS400 Series, TDS500 Series, TDS5000 Series, TDS600 Series, TDS700 Series, TDS7000 Series | ||
Model Number p ADA400A | ||
Exempt
- COO (Country of Origin):
- US
Tektronix ADA400A 1 MHz Differential Preamplifier
The ADA400A Active Differential Preamplifier allows direct oscilloscope measurements of very low amplitude voltages and signals which are not ground referenced. The high impedance of both inputs eliminates the need to add additional ground points in the DUT, thereby avoiding circulating currents which disturb the measurement or the circuit.,The high gain and extremely high common mode rejection provide usable measurements of voltages as low as 5μV, even in high noise environments. Selectable bandwidth limiting reduces normal mode noise from digital logic, switch mode power supplies and line frequency sources. Adjustable differential offset allows the user to null out transducer bridge bias and galvanic potential from the test set-up. An "infinite impedance" mode can be selected in the two highest gain ranges allowing accurate measurements of signals with high source impedance. It is specifically designed to operate on Tektronix oscilloscopes with TEKPROBE® interface
10μV/div Sensitivity
Low-pass filter: 100Hz, 3kHz, 100Hz or Full (1 MHz)
Typically 100 dB CMRR DC to 10 kHz
Selectable Gain: 100, 10, 1 or 0.1
Accurately measures signal as small as 5uV
Integral Probe Power with TEKPROBE™BNC
Low-pass filter: 100Hz, 3kHz, 100Hz or Full (1 MHz)
Typically 100 dB CMRR DC to 10 kHz
Selectable Gain: 100, 10, 1 or 0.1
Accurately measures signal as small as 5uV
Integral Probe Power with TEKPROBE™BNC
Tektronix ADA400A 1 MHz Differential Preamplifier
10μV/div Sensitivity
Low Pass filters for 100Hz, 3kHz, 100Hz and Full (1 MHz)
Typically 100 dB CMRR DC to 10 kHz
Selectable Gain: 100, 10, 1 or 0.1
Accurately measures signal as small as 5uV
Integral Probe Power with TEKPROBE ™ BNC
Low Pass filters for 100Hz, 3kHz, 100Hz and Full (1 MHz)
Typically 100 dB CMRR DC to 10 kHz
Selectable Gain: 100, 10, 1 or 0.1
Accurately measures signal as small as 5uV
Integral Probe Power with TEKPROBE ™ BNC
The ADA400A Active Differential Preamplifier allows direct oscilloscope measurements of very low amplitude voltages and signals which are not ground referenced. The high impedance of both inputs eliminates the need to add additional ground points in the DUT, thereby avoiding circulating currents which disturb the measurement or the circuit.
The high gain and extremely high common mode rejection provide usable measurements of voltages as low as 5μV, even in high noise environments. Selectable bandwidth limiting reduces normal mode noise from digital logic, switch mode power supplies and line frequency sources. Adjustable differential offset allows the user to null out transducer bridge bias and galvanic potential from the test set-up. An "infinite impedance" mode can be selected in the two highest gain ranges allowing accurate measurements of signals with high source impedance. It is specifically designed to operate on Tektronix oscilloscopes with TEKPROBE® interface.
The high gain and extremely high common mode rejection provide usable measurements of voltages as low as 5μV, even in high noise environments. Selectable bandwidth limiting reduces normal mode noise from digital logic, switch mode power supplies and line frequency sources. Adjustable differential offset allows the user to null out transducer bridge bias and galvanic potential from the test set-up. An "infinite impedance" mode can be selected in the two highest gain ranges allowing accurate measurements of signals with high source impedance. It is specifically designed to operate on Tektronix oscilloscopes with TEKPROBE® interface.
Related links
- Tektronix Oscilloscope Battery Power Supply 1103 P5205 P6205 P6245
- Tektronix DPO2COMP Analysis Module, Computer Serial Triggering Oscilloscope Module for Use with MSO/DPO2000 Series
- Tektronix DPO4USB Analysis Module, USB Serial Triggering Oscilloscope Module for Use with MDO4000 Series
- Tektronix DPO4EMBD Analysis Module
- Tektronix TEK DPG Deskew Pulse Generator Oscilloscope Module for Use with DPO/MSO4000 Series, DPO3000 Series
- Tektronix MDO3MSO Analysis Module Oscilloscope Module for Use with MDO3000 Series
- Tektronix MDO3AUTO Analysis Module Oscilloscope Module for Use with MDO3000 Series
- Tektronix MDO3AFG Analysis Module Oscilloscope Module for Use with MDO3000 Series
