Fluke 3000 FC 3000 FC Handheld Digital Multimeter True RMS, 400 mA ac, 400 mA dc, 1 kV ac
- RS stock no.:
- 811-1316
- Distrelec Article No.:
- 110-83-815
- Mfr. Part No.:
- FLK-3000 FC
- Manufacturer:
- Fluke
Image representative of range
Subtotal (1 unit)*
R 10 590,00
(exc. VAT)
R 12 178,50
(inc. VAT)
FREE delivery for orders over R 1,500.00
- Shipping from 20 April 2026
Units | Per unit |
|---|---|
| 1 + | R 10,590.00 |
*price indicative
- RS stock no.:
- 811-1316
- Distrelec Article No.:
- 110-83-815
- Mfr. Part No.:
- FLK-3000 FC
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Multimeter Type | Handheld | |
| Product Type | Multimeter | |
| Display Type | Digital | |
| Model Number | 3000 FC | |
| Resistance Resolution | 100mΩ | |
| Functions Measured | AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | |
| Maximum Resistance Measurement | 50mΩ | |
| Maximum AC Voltage Measurement | 1kV ac | |
| Maximum DC Current Measurement | 400mA dc | |
| Maximum AC Current Measurement | 400mA ac | |
| Maximum DC Voltage Measurement | 1kV dc | |
| True RMS | Yes | |
| DC Current Accuracy | ±0.5 % | |
| AC Current Accuracy | ±1.5 % | |
| DC Voltage Accuracy | ±0.09 % | |
| AC Voltage Accuracy | ±1 % rdg | |
| DC Current Resolution | 0.01mA dc | |
| AC Current Resolution | 0.01mA ac | |
| AC Voltage Resolution | 0.1mV ac | |
| DC Voltage Resolution | 0.1 mV dc | |
| Maximum Frequency | 99.99kHz | |
| Minimum Operating Temperature | -10°C | |
| Resistance Measurement Accuracy | ±0.5 % rdg | |
| Maximum Operating Temperature | 50°C | |
| Battery Life | 250h | |
| Length | 207mm | |
| Standards/Approvals | No | |
| Series | 3000 FC | |
| Height | 47.5mm | |
| Weight | 487.5g | |
| Safety Category Level | CAT III, CAT IV | |
| Battery Type | AA | |
| Safety Category Voltage | 1000V | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Multimeter Type Handheld | ||
Product Type Multimeter | ||
Display Type Digital | ||
Model Number 3000 FC | ||
Resistance Resolution 100mΩ | ||
Functions Measured AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | ||
Maximum Resistance Measurement 50mΩ | ||
Maximum AC Voltage Measurement 1kV ac | ||
Maximum DC Current Measurement 400mA dc | ||
Maximum AC Current Measurement 400mA ac | ||
Maximum DC Voltage Measurement 1kV dc | ||
True RMS Yes | ||
DC Current Accuracy ±0.5 % | ||
AC Current Accuracy ±1.5 % | ||
DC Voltage Accuracy ±0.09 % | ||
AC Voltage Accuracy ±1 % rdg | ||
DC Current Resolution 0.01mA dc | ||
AC Current Resolution 0.01mA ac | ||
AC Voltage Resolution 0.1mV ac | ||
DC Voltage Resolution 0.1 mV dc | ||
Maximum Frequency 99.99kHz | ||
Minimum Operating Temperature -10°C | ||
Resistance Measurement Accuracy ±0.5 % rdg | ||
Maximum Operating Temperature 50°C | ||
Battery Life 250h | ||
Length 207mm | ||
Standards/Approvals No | ||
Series 3000 FC | ||
Height 47.5mm | ||
Weight 487.5g | ||
Safety Category Level CAT III, CAT IV | ||
Battery Type AA | ||
Safety Category Voltage 1000V | ||
Exempt
- COO (Country of Origin):
- US
Fluke Multimeter, 1000V Maximum DC Voltage, True RMS Functionality - FLK-3000 FC
Features & Benefits
• True RMS measurement for accurate non‑sinusoidal waveforms
• 400 mA maximum current range for precision current checks
• Frequency measurement to 99.99 kHz for signal verification
• Resistance down to 50 mΩ for low‑ohm integrity testing
• AA battery operation with 250 h minimum battery life for prolonged field use
Applications
• Ideal for preventative maintenance log collection and trend analysis
• Used for motor drive frequency and signal validation in automation systems
• Can be used for HVAC temperature checks via K‑type probes
• Used with remote clamp modules for non‑intrusive current monitoring
How is logged data retrieved for analysis on a PC?
What wireless range can be expected through typical site obstacles?
How does the instrument handle non‑sine AC voltages for accuracy?
What logging capacity and granularity are available for extended monitoring?
Which environmental conditions affect measurement performance?
Note
Supplied with
Related links
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS 1000 V ac Max
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter 1000 V ac Max
- Fluke Fluke 279 FC Handheld Digital Multimeter True RMS, 2.5 kA Max
- RS PRO S2 Handheld Digital Multimeter True RMS 400 mA Max, 1000 V ac Max
- Facom 714APF Handheld Multimeter True RMS 400 mA Max, 600 V ac Max
- Fluke 279 FC Handheld LCD Thermal Imaging Multimeter 2.5kA ac Max, 1000V ac Max
- RS PRO RS-218 Handheld Digital Multimeter True RMS 200 mA Max, 600 V ac Max
- Fluke Fluke 117 Digital Digital Multimeter Kit True RMS 10 A dc Max, 600 V ac Max
