Fluke 1654 Electrical Tester, 50 V, 100 V, 250 V, 500 V, 1000 V , Earth Resistance Measurement With UK Mains

Image representative of range

Unavailable
RS will no longer stock this product.
RS stock no.:
741-4352
Mfr. Part No.:
Fluke 1654B/DMS
Manufacturer:
Fluke
Find similar products by selecting one or more attributes.
Select all

Brand

Fluke

Loop Impedance Test Type

3 Wire

Automatic RCD Test

Yes

Model Number p

1654

RCD Ramp Test

Yes

Non-Tripping

Yes

Insulation Test Voltage

50 V, 100 V, 250 V, 500 V, 1000 V

Maximum Voltage Measurement

500V ac

Test Type

Continuity, Wiring Polarity

Earth Resistance Measurement

Yes

Interface Type

UK Mains

Continuity Test Current

200mA

RCD Test Type

AC Type, DC Selective

IP Rating

IP40

Test Standards

EN 61010-I, HD 384, IEC 60364

Dimensions

100 x 250 x 125mm

Safety Category Level

CAT III, CAT IV

Weight

1.3kg

Height

125mm

Minimum Operating Temperature

-10°C

Length

100mm

Width

250mm

Minimum Continuity Resistance

20Ω

Power Source

Battery, Mains

Maximum Operating Temperature

+40°C

Display Type

LCD

Safety Category

CAT III 500 V, CAT IV 300 V

Battery Type

AA

Safety Category Voltage

300 V, 500 V

Maximum Continuity Resistance

2000Ω

Non Compliant

Fluke 1654B / DMS Pro Software (UK version)


The Fluke 1654B multifunction tester has been designed for the requirements of the commercial and industrial installer. With extra insulation test voltages, phase rotation and earth resistance testing with the optional spike kit (Fluke ES165X), the Fluke 1654B includes the DMS Installer Professional software, allowing you to download and print NIC EIC certificates.This new model greatly improves on the previous Fluke 1654, with the addition of the high current loop test as well as speeding up the time taken to perform the tests. The memory function can store up to 1500 test results

Performs Insulation test at 50, 100, 250, 500 or 1000VNon-trip loop test won't trip out RCDs, and now the B version also includes a high current loop test0.001Ω resolution on high current loop test Auto RCD test, Ramp test & RCD trip time test with variable RCD current mode for customised settings & Pass / Fail indicationRCD Type B Test (smooth DC current) PEFC / PSC (PFC / PSCC) & loop measurements are displayed at the same time Earth resistance test (optional spike kit required)Phase rotationLive voltage indicator and wiring polarity checker6 x 1.5 Alkaline Cells Type LR6 Battery Life: 3000 continuity tests Free manufacturers calibration certificate included

Supplied with