Telemecanique Sensors XCSM Series Rotary Lever Limit Switch, 2 NO/2 NC, IP68, IP67, IP66, Metal Housing, 240V ac, 1.5A
- RS stock no.:
- 766-1731
- Mfr. Part No.:
- XCSM4116L1
- Manufacturer:
- Telemecanique Sensors
Subtotal (1 unit)*
R 2 676,97
(exc. VAT)
R 3 078,52
(inc. VAT)
FREE delivery for orders over R 1,500.00
In Stock
- 9 unit(s) ready to ship from another location
- Plus 5 unit(s) shipping from 24 September 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | R 2,676.97 |
*price indicative
- RS stock no.:
- 766-1731
- Mfr. Part No.:
- XCSM4116L1
- Manufacturer:
- Telemecanique Sensors
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Telemecanique Sensors | |
| Product Type | Limit Switch | |
| Actuator Type | Rotary Lever | |
| Contact Configuration | 2 NO/2 NC | |
| IP Rating | IP68, IP67, IP66 | |
| Housing Material | Metal | |
| Contact Type | Snap Action | |
| Switching Current | 1.5A | |
| Terminal Type | Cable | |
| Series | XCSM | |
| Switching AC Voltage | 240V ac | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 70°C | |
| Width | 30mm | |
| Depth | 34mm | |
| Length | 94mm | |
| Standards/Approvals | CE, RoHS, UL, EN, CSA, IEC | |
| Hazardous Area Certification | No | |
| Mechanical Life | 10000000Cycles | |
| Select all | ||
|---|---|---|
Brand Telemecanique Sensors | ||
Product Type Limit Switch | ||
Actuator Type Rotary Lever | ||
Contact Configuration 2 NO/2 NC | ||
IP Rating IP68, IP67, IP66 | ||
Housing Material Metal | ||
Contact Type Snap Action | ||
Switching Current 1.5A | ||
Terminal Type Cable | ||
Series XCSM | ||
Switching AC Voltage 240V ac | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 70°C | ||
Width 30mm | ||
Depth 34mm | ||
Length 94mm | ||
Standards/Approvals CE, RoHS, UL, EN, CSA, IEC | ||
Hazardous Area Certification No | ||
Mechanical Life 10000000Cycles | ||
- COO (Country of Origin):
- ID
Telemecanique Sensors XCSM Series Limit Switch, IP68, IP67, IP66, 10000000 Cycles Mechanical Life - XCSM4116L1
This limit switch provides position detection for industrial and machinery control applications using a rotary lever actuator. It is designed for environments where sealed operation and snap-action contact performance are needed, delivering electrical switching for both AC and DC circuits while operating across a broad ambient temperature range.
Features and Benefits:
• Metal housing offers robust protection and long service life
• Snap-action contacts enable fast, reliable switching response
• 2NO/2NC contact layout supports versatile circuit configurations
• Switching up to 250V DC meets high-voltage DC control needs
• Rated for 240V AC switching at 1.5A for moderate-load circuits
• Mechanical endurance of 10,000,000 cycles minimises replacement frequency
• Snap-action contacts enable fast, reliable switching response
• 2NO/2NC contact layout supports versatile circuit configurations
• Switching up to 250V DC meets high-voltage DC control needs
• Rated for 240V AC switching at 1.5A for moderate-load circuits
• Mechanical endurance of 10,000,000 cycles minimises replacement frequency
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for use in automated actuator position-sensing systems
• Used for safety interlock monitoring on industrial doors
• Can be used for limit detection in packaging machinery
• Appropriate for valve position feedback in process plants
• Ideal for use in automated actuator position-sensing systems
• Used for safety interlock monitoring on industrial doors
• Can be used for limit detection in packaging machinery
• Appropriate for valve position feedback in process plants
What ingress protection levels are available for use in wet conditions?
It is supplied with IP68, IP67 and IP66 ingress ratings to suit different degrees of water and dust exposure.
How is the device connected electrically on-site?
Connections are provided via a cable-termination arrangement for direct wiring to control circuits.
What operating temperatures will sustain normal function?
The unit operates reliably between -25°C and 70°C ambient temperatures.
Which standards approvals accompany this switch?
It carries approvals including CE, RoHS, UL, EN, CSA and IEC.
What switching behaviour can be expected from the contacts?
The contacts employ a snap-action mechanism to provide Rapid make-and-break operation under load.
Note
With the appropriate monitoring system and correctly wired these switches can reach safety category 4 conforming to EN/ISO 13849-1, PL e conforming to EN/ISO 13849-1, SIL 3 conforming to EN/IEC 61508.
Approvals
UL, CSA.
Standards
CSA C22-2 No 14, EN 1088, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508.
Related links
- Telemecanique Sensors XCSM Series Roller Lever Limit Switch IP68 IP66 240V ac, 1.5A
- Telemecanique Sensors XCSM Series Roller Lever Limit Switch IP67 IP66 240V ac, 1.5A
- Telemecanique Sensors XCSM Series Roller Lever Limit Switch IP68 IP66 1.5A
- Telemecanique Sensors XCSM Series Roller Lever Limit Switch IP66 IP68 240V ac, 1.5A
- Telemecanique Sensors XCSM Series Plunger Limit Switch IP68 IP66 240V ac, 1.5A
- Telemecanique Sensors XCSM Series Roller Plunger Interlock Switch IP68 Metal Housing 1.5A
- Telemecanique Sensors XCSM Series Thermoplastic roller lever Limit Switch IP68 IP66
- Telemecanique Sensors XCSM Series Roller Lever Limit Switch IP66 IP68 240V ac, 3A
