Telemecanique Sensors XCKP Series Plunger Limit Switch, 1 NO/1 NC, IP67, IP66, Plastic Housing, 240V ac, 10A
- RS stock no.:
- 195-1682
- Mfr. Part No.:
- XCKP2510G11
- Manufacturer:
- Telemecanique Sensors
Subtotal (1 unit)*
R 784,63
(exc. VAT)
R 902,32
(inc. VAT)
FREE delivery for orders over R 1,500.00
In Stock
- 18 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | R 784.63 |
*price indicative
- RS stock no.:
- 195-1682
- Mfr. Part No.:
- XCKP2510G11
- Manufacturer:
- Telemecanique Sensors
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Telemecanique Sensors | |
| Actuator Type | Plunger | |
| Product Type | Limit Switch | |
| IP Rating | IP67, IP66 | |
| Contact Configuration | 1 NO/1 NC | |
| Housing Material | Plastic | |
| Contact Type | Slow Break | |
| Switching Current | 10A | |
| Terminal Type | Screw Clamp | |
| Series | XCKP | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -25°C | |
| Switching AC Voltage | 240V ac | |
| Maximum Operating Temperature | 70°C | |
| Width | 30mm | |
| Depth | 65mm | |
| Length | 31mm | |
| Standards/Approvals | RoHS | |
| Hazardous Area Certification | No | |
| Conduit Entry | M20 | |
| Mounting Orientation | Cable | |
| Operating Force | 45N | |
| Mechanical Life | 15000000Cycles | |
| Select all | ||
|---|---|---|
Brand Telemecanique Sensors | ||
Actuator Type Plunger | ||
Product Type Limit Switch | ||
IP Rating IP67, IP66 | ||
Contact Configuration 1 NO/1 NC | ||
Housing Material Plastic | ||
Contact Type Slow Break | ||
Switching Current 10A | ||
Terminal Type Screw Clamp | ||
Series XCKP | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -25°C | ||
Switching AC Voltage 240V ac | ||
Maximum Operating Temperature 70°C | ||
Width 30mm | ||
Depth 65mm | ||
Length 31mm | ||
Standards/Approvals RoHS | ||
Hazardous Area Certification No | ||
Conduit Entry M20 | ||
Mounting Orientation Cable | ||
Operating Force 45N | ||
Mechanical Life 15000000Cycles | ||
- COO (Country of Origin):
- ID
Telemecanique Sensors XCKP Series Limit Switch, IP67, 10A Switching Current - XCKP2510G11
This limit switch is a plunger-operated device designed to detect mechanical position changes and provide switching for control systems in industrial environments. It is housed in plastic with cable mounting orientation and offers a slow-break contact arrangement to manage switching tasks across DC and AC circuits while operating across a broad temperature range.
Features and Benefits:
• IP67 and IP66 protection for use in wet environments
• 1NO/1NC slow-break contacts for controlled switching behaviour
• 10A switching current to handle moderate load circuits
• 240V AC and 250V DC switching capability for mixed systems
• Operating force 45N to ensure consistent actuation response
• Mechanical life 15,000,000 cycles for extended operational durability
• 1NO/1NC slow-break contacts for controlled switching behaviour
• 10A switching current to handle moderate load circuits
• 240V AC and 250V DC switching capability for mixed systems
• Operating force 45N to ensure consistent actuation response
• Mechanical life 15,000,000 cycles for extended operational durability
Applications
• Suitable for conveyor end-of-travel detection
• Ideal for machine tool position feedback
• Used with actuators in assembly automation
• Can be used for safety interlock monitoring
• Suitable for panel-mounted control signal input
• Ideal for machine tool position feedback
• Used with actuators in assembly automation
• Can be used for safety interlock monitoring
• Suitable for panel-mounted control signal input
What Terminal arrangement does it provide for wiring?
It uses screw-clamp terminals to secure conductor connections.
How is the conduit or cable routed into the enclosure?
Entry is provided via an M20 conduit Interface for gland or conduit attachment.
What temperature extremes can it operate within?
The device functions across a range from -25°C to 70°C.
What contact behaviour should be expected during switching?
Contacts operate as slow-break type, reducing arcing on opening.
Is it certified for use in explosive atmospheres?
It does not carry hazardous area certification.
Related links
- Telemecanique Sensors XCKP Series Roller Lever Limit Switch IP67 Plastic Housing 10A
- Telemecanique Sensors XCKP Series Lever Limit Switch IP67 Plastic Housing 10A
- Telemecanique Sensors XCKP Series Plunger Limit Switch IP67 Plastic Housing 10A
- Telemecanique Sensors XCKP Series Roller Plunger Limit Switch IP67 Plastic Housing 10A
- Telemecanique Sensors XCKP Series Plunger Limit Switch IP66 Plastic Housing 10A
- Telemecanique Sensors XCKP Series Roller Lever Limit Switch IP66 Plastic Housing 10A
- Telemecanique Sensors XCKP Series Lever Limit Switch IP66 Plastic Housing 10A
- Telemecanique Sensors XCKP Series Roller Plunger Limit Switch IP66 Plastic Housing 10A