Telemecanique Sensors XCMH Series Roller Plunger Limit Switch, 1 NO/1 NC, IP66, IP67, Plastic Housing, 240V ac, 0.75A
- RS stock no.:
- 194-141
- Mfr. Part No.:
- XCMH2103L1
- Manufacturer:
- Telemecanique Sensors
Subtotal (1 unit)*
R 959,34
(exc. VAT)
R 1 103,24
(inc. VAT)
FREE delivery for orders over R 1,500.00
In Stock
- 105 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | R 959.34 |
*price indicative
- RS stock no.:
- 194-141
- Mfr. Part No.:
- XCMH2103L1
- Manufacturer:
- Telemecanique Sensors
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Telemecanique Sensors | |
| Product Type | Limit Switch | |
| Actuator Type | Roller Plunger | |
| Contact Configuration | 1 NO/1 NC | |
| IP Rating | IP66, IP67 | |
| Housing Material | Plastic | |
| Contact Type | Snap Action | |
| Switching Current | 0.75A | |
| Terminal Type | Cable | |
| Series | XCMH | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 240V ac | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 70°C | |
| Depth | 70.4mm | |
| Length | 16mm | |
| Standards/Approvals | UL 508, CSA C22.2 No 14, IEC 60204-1, IEC 60947-5-1 | |
| Width | 30mm | |
| Hazardous Area Certification | No | |
| Mechanical Life | 5000000Cycles | |
| Operating Force | 35N | |
| Select all | ||
|---|---|---|
Brand Telemecanique Sensors | ||
Product Type Limit Switch | ||
Actuator Type Roller Plunger | ||
Contact Configuration 1 NO/1 NC | ||
IP Rating IP66, IP67 | ||
Housing Material Plastic | ||
Contact Type Snap Action | ||
Switching Current 0.75A | ||
Terminal Type Cable | ||
Series XCMH | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 240V ac | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 70°C | ||
Depth 70.4mm | ||
Length 16mm | ||
Standards/Approvals UL 508, CSA C22.2 No 14, IEC 60204-1, IEC 60947-5-1 | ||
Width 30mm | ||
Hazardous Area Certification No | ||
Mechanical Life 5000000Cycles | ||
Operating Force 35N | ||
- COO (Country of Origin):
- ID
Telemecanique Sensors XCMH Series Limit Switch, IP66/IP67 Ingress Protection, 0.75A Switching Current - XCMH2103L1
This limit switch provides electromechanical position detection for industrial machinery, operating as a roller plunger actuator to monitor movement and trigger control circuits. It is designed for use in demanding environments where robust switching and clear contact changeover are required, offering snap-action contacts and cable termination for straightforward integration into control systems.
Features and Benefits:
• Snap-action contacts deliver quick, positive switching
• 1NO1NC configuration supports dual-circuit control
• 35N actuator force ensures consistent actuation
• Rated for 0.75A switching current for low-power circuits
• Conforms to IEC 60947-5-1 for recognised switching performance
• 1NO1NC configuration supports dual-circuit control
• 35N actuator force ensures consistent actuation
• Rated for 0.75A switching current for low-power circuits
• Conforms to IEC 60947-5-1 for recognised switching performance
Applications
• Suitable for conveyor end-of-travel detection
• Ideal for safety interlocks on guarding doors
• Used with indexing mechanisms for position feedback
• Can be used for machine tool limit sensing
• Appropriate for automated packaging position control
• Ideal for safety interlocks on guarding doors
• Used with indexing mechanisms for position feedback
• Can be used for machine tool limit sensing
• Appropriate for automated packaging position control
What temperature range can it operate within?
It functions over an ambient span from -25°C up to 70°C, accommodating cold starts and warm production environments.
How long is its expected mechanical service life?
The unit is specified for 5,000,000 mechanical cycles, indicating suitability for frequent actuation applications.
What voltages can the contacts switch?
The contacts are rated to switch up to 240V AC and 250V DC, enabling compatibility with common control voltages.
What ingress protection does the enclosure provide?
The housing meets IP66 and IP67 levels, offering protection against dust and temporary or high-pressure water exposure.
Related links
- Telemecanique Sensors XCMH Series Roller Plunger Limit Switch IP66 Plastic Housing 0.75A
- Telemecanique Sensors XCMH Series Roller Plunger Limit Switch IP66 Plastic Housing 0.75A
- Telemecanique Sensors XCMH Series Roller Plunger Limit Switch IP67 Plastic Housing 0.75A
- Telemecanique Sensors XCMH Series Plunger Limit Switch IP66 Plastic Housing 0.75A
- Telemecanique Sensors XCMH Series Roller Lever Limit Switch IP66 Plastic Housing 0.75A
- Telemecanique Sensors XCMH Series Roller Lever Limit Switch IP67 Plastic Housing 0.75A
- Telemecanique Sensors XCMH Series Roller Plunger Limit Switch IP66 Plastic Housing 0.75A
- Telemecanique Sensors XCMH Series Plunger Limit Switch IP67 Plastic Housing 0.75A