Gossen Metrawatt METRISO PRIME Insulation Tester, 100 V Min, 5 kV Max, 100 GΩ CAT IV, CAT III, CAT II
- RS stock no.:
- 867-5630
- Distrelec Article No.:
- 300-18-121
- Mfr. Part No.:
- M550T
- Manufacturer:
- Gossen Metrawatt
Image representative of range
Subtotal (1 unit)*
R 36 019,46
(exc. VAT)
R 41 422,38
(inc. VAT)
FREE delivery for orders over R 1,500.00
In Stock
- 5 unit(s) ready to ship from another location
- Plus 8 unit(s) shipping from 30 November 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | R 36,019.46 |
*price indicative
- RS stock no.:
- 867-5630
- Distrelec Article No.:
- 300-18-121
- Mfr. Part No.:
- M550T
- Manufacturer:
- Gossen Metrawatt
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Gossen Metrawatt | |
| Product Type | Insulation Tester | |
| Model Number | METRISO PRIME | |
| Tester Type | Insulation Tester | |
| Minimum Test Voltage | 100V | |
| Maximum Test Voltage | 5kV | |
| Display Type | Analogue | |
| Test Current | 1mA | |
| Battery Type | Type D | |
| Power Source | Battery | |
| Minimum Operating Temperature | 0°C | |
| Insulation Testing Resistance | 100GΩ | |
| Safety Category Voltage | 1kV | |
| Maximum Operating Temperature | 40°C | |
| Safety Category Level | CAT IV, CAT III, CAT II | |
| Width | 290mm | |
| Standards/Approvals | CE | |
| Length | 250mm | |
| Height | 140mm | |
| Weight | 3.4kg | |
| Select all | ||
|---|---|---|
Brand Gossen Metrawatt | ||
Product Type Insulation Tester | ||
Model Number METRISO PRIME | ||
Tester Type Insulation Tester | ||
Minimum Test Voltage 100V | ||
Maximum Test Voltage 5kV | ||
Display Type Analogue | ||
Test Current 1mA | ||
Battery Type Type D | ||
Power Source Battery | ||
Minimum Operating Temperature 0°C | ||
Insulation Testing Resistance 100GΩ | ||
Safety Category Voltage 1kV | ||
Maximum Operating Temperature 40°C | ||
Safety Category Level CAT IV, CAT III, CAT II | ||
Width 290mm | ||
Standards/Approvals CE | ||
Length 250mm | ||
Height 140mm | ||
Weight 3.4kg | ||
- COO (Country of Origin):
- DE
Gossen-Metrawatt Insulation Tester, 5000V Maximum Test Voltage, 100GΩ Insulation Testing Resistance - M550T
This insulation tester is a battery-powered, analogue instrument designed to measure high resistance in electrical systems. It operates across a broad test-voltage range and is suitable for field use where portable diagnostics are required. The unit is intended for use within standard ambient temperatures and conforms to recognised safety approvals for industrial environments.
Features and Benefits:
• *Made in Germany
• 5000 V maximum test voltage provides wide-range dielectric assessment
• 100 GΩ insulation measurement supports detection of very high resistances
• 1 mA test current allows controlled energisation during tests
• Battery operation using Type D cells enables remote-site use
• CAT IV safety rating permits work on high-energy installations
• 5000 V maximum test voltage provides wide-range dielectric assessment
• 100 GΩ insulation measurement supports detection of very high resistances
• 1 mA test current allows controlled energisation during tests
• Battery operation using Type D cells enables remote-site use
• CAT IV safety rating permits work on high-energy installations
Applications
• Used for verification of insulation on industrial switchgear
• Suitable for maintenance of electrical distribution networks
• Ideal for commissioning tests on high-voltage equipment
• Used for routine insulation diagnostics in plant environments
• Suitable for portable fault-finding across service installations
• Suitable for maintenance of electrical distribution networks
• Ideal for commissioning tests on high-voltage equipment
• Used for routine insulation diagnostics in plant environments
• Suitable for portable fault-finding across service installations
What supply does the instrument require to operate?
It runs from replaceable Type D batteries and is intended for off-mains use.
Which safety categories cover its intended use?
The device meets CAT IV, CAT III and CAT II safety levels for various installation points.
What display format is provided for readings?
Readouts are presented on an analogue scale to monitor measurement behaviour.
What environmental temperatures can it tolerate during operation?
It is rated to operate between 0°C and 40°C.
Related links
- Gossen Metrawatt METRISO TECH Insulation Tester 1 kV Max CAT IV, CAT III
- Gossen Metrawatt METRISO 1000A Insulation Tester 1 kV Max, 400 MΩ CAT II
- Gossen Metrawatt M246C Insulation Tester 1 kV Max CAT II
- Beha-Amprobe 93530 Insulation Tester 1 kV Max CAT III
- RS PRO RSLC-10000 Insulation Tester 240 V Max CAT II
- Megger MIT525 Insulation Tester 5 kV Max 600 V CAT III
- Chauvin Arnoux CA 6503 Insulation Tester 1 kV Max CAT II
- Fluke 1550C Insulation Tester 5 kV Max CAT III