Eaton 400 A Fuse Holder, 3P-Pole for NH2 Fuse

Subtotal (1 unit)*

R 25 753,60

(exc. VAT)

R 29 616,64

(inc. VAT)

Add to Basket
Select or type quantity
Temporarily out of stock
  • Shipping from 27 April 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +R 25,753.60

*price indicative

RS stock no.:
127-396
Mfr. Part No.:
183070 XNH2-FCE-S400-BT
Manufacturer:
Eaton
Find similar products by selecting one or more attributes.
Select all

Brand

Eaton

Product Type

Fuse Holder

Current Rating

400 A

Number of Poles

3

Body Material

Polyamide

IP Rating

IP2XC, IP20, IP10

Compatible Fuse Size

NH2 Fuse

Minimum Operating Temperature

-5°C

Maximum Operating Temperature

55°C

Standards/Approvals

IEC/EN 61439, RoHS

Series

XNH2

Terminal Type

Clamp

Exempt

COO (Country of Origin):
DE

Eaton xEffect Series Fuse Holder, 400A Current, 800V Voltage - 183070 XNH2-FCE-S400-BT


This fuse holder is a three-pole device designed for mounting on 60mm busbars, providing electronic monitoring of NH2 fuse-links in industrial switchgear. It is intended for front-access installation with box-type terminals and a cover-grip actuator, enabling safe insertion and live-handle operation where space is constrained and centralised distribution is required.

Features & Benefits


• Rated for 400A continuous operation delivering high current capacity
• 800V insulation rating enabling elevated voltage system use
• Electronic fuse monitoring offers LED indication and relay output
• Conditioned short-circuit capacity 120 kA improves fault handling
• IP20 protection on the front reduces risk during normal operation
• Permits 95 to 300mm² fuse conductors for broad conductor compatibility

Applications


• Suitable for distribution panels in industrial automation systems
• Ideal for integration in low-voltage switchgear assemblies
• Used with central busbar systems for power distribution
• Can be used for protective switching in motor control centres
• Suitable for retrofit of NH2 fuse arrangements in factories

What type of terminals are provided for main connections?


The device uses box terminals and frame-clamp connections with flange bolt M10 accommodation and supports wide cable lug widths up to 48mm.

How does the monitoring Interface signal a fault condition?


It provides three red LEDs for individual pole fault indication, one green LED for supply, Plus one normally open and one normally closed contact for relay signalling.

What are the thermal and environmental operating limits?


The ambient operating range spans -25 °C to 55 °C with a maximum continuous operating temperature rating of 70 °C for component limits.

Which electrical endurance and mechanical lifespans apply?


The unit is specified for 200 electrical operations and 800 mechanical operations under normal use.

What materials and fire performance are specified for insulating parts?


The enclosure is MADE from polyamide and meets self‑extinguishing criteria consistent with UL94 flammability characteristics.

Related links