Eaton 160 A Fuse Holder, 3P-Pole for NH000/NH00 Fuse

Subtotal (1 unit)*

R 4 443,95

(exc. VAT)

R 5 110,54

(inc. VAT)

Add to Basket
Select or type quantity
Stock information currently inaccessible - Please check back later
Units
Per unit
1 +R 4,443.95

*price indicative

RS stock no.:
127-224
Mfr. Part No.:
183038 XNH00-FCL-S160-BT2
Manufacturer:
Eaton
Find similar products by selecting one or more attributes.
Select all

Brand

Eaton

Product Type

Fuse Holder

Number of Poles

3

Body Material

Polyamide

IP Rating

IP10, IP20, IP2XC

Minimum Operating Temperature

-5°C

Compatible Fuse Size

NH000/NH00 Fuse

Maximum Operating Temperature

55°C

Standards/Approvals

IEC/EN 61439, RoHS

Series

XNH00

Terminal Type

Clamp

COO (Country of Origin):
DE

Eaton xEffect Series Fuse Holder, 160A Current, 800V Voltage - 183038 XNH00-FCL-S160-BT2


This fuse holder is a three-pole device designed for use on 60mm busbar systems to allow safe insertion and monitoring of NH000 and NH00 fuse-links in industrial switchgear. It provides a front-access actuator and Visual indication of a triggered fuse, enabling straightforward maintenance and inspection within control, automation and electrical distribution assemblies.

Features & Benefits


• Rated for 160A continuous current giving high-current operation
• Insulation rating Ui 800V AC supports elevated system voltages
• Conditional short-circuit rating 120 kA reduces fault exposure
• Optical signalling of triggered fuses enables fast fault localisation
• Box Terminal accepts 1.5mm² to 95mm² simplifying cable termination
• Operating temperature range −25 °C to 70 °C permits harsh environments

Applications


• Suitable for busbar-mounted distribution panels in factories
• Ideal for switchgear in automation control cabinets
• Used for protection of motor starter circuits in industrial plants
• Can be used for retrofit of NH00 fuse-links in electrical rooms
• Suitable for systems requiring front-side control and inspection

What Terminal options are available for incoming and outgoing conductors?


The device uses a lowered box Terminal arrangement with capacity for single conductors up to 95mm² and accepts copper strips and lugs via an M8 flange bolt interface.

How does the unit indicate a blown fuse without opening the panel?


It provides optical signalling through inspection windows so a triggered fuse-link is visible while remaining installed.

What mechanical mounting orientations are permitted?


It can be mounted vertically or horisontally on a 60mm busbar system to suit panel layout constraints.

Are there provisions for locking or securing the actuator?


A locking facility is available as an option to secure the front-side cover grip during maintenance.

What are endurance expectations for mechanical and electrical operations?


The device is rated for approximately 1,400 mechanical operations and 300 electrical operations under specified conditions.