Fluke I30S Current Clamp, 20 A DC Max, AC/DC Adapter, 20 A AC Max, Voltage Output

Image representative of range

Subtotal (1 unit)*

R 25 778,98

(exc. VAT)

R 29 645,83

(inc. VAT)

Add to Basket
Select or type quantity
Stocked by manufacturer
  • Ready to ship from 12 October 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +R 25,778.98

*price indicative

RS stock no.:
645-1836
Distrelec Article No.:
176-12-682
Mfr. Part No.:
I30S
Manufacturer:
Fluke
Find similar products by selecting one or more attributes.
Select all

Brand

Fluke

Adapter Type

AC/DC

Product Type

Current Clamp

Maximum DC Current

20A

Maximum AC Current

20A

Accuracy

±1% + 2 mA

Maximum Conductor Size

19mm

Cable Length

2m

Output Type

Voltage

Connector Type

BNC

Battery Type

Alkaline

Battery Life

30h

Minimum Operating Temperature

0°C

Maximum Operating Temperature

50°C

Model Number

I30S

Standards/Approvals

IEC 61326-1

Safety Category Level

CAT III

Safety Category Voltage

300V

Exempt

COO (Country of Origin):
CN

Fluke Current Clamp, 30A Maximum DC Current, 20A Maximum AC Current - I30S


This current clamp measures both AC and DC currents using Hall-effect sensing for non-intrusive recordings with oscilloscopes and similar instruments, and is designed for field and bench use where isolation from the conductor is required.

Features and Benefits:


• 30mA-30A DC range delivers wide measurement capability for varied loads
• 30mA-20A AC rms range supports common mains and control circuits
• Output sensitivity 100mV/A provides direct voltage output to instruments
• Accuracy ±1% of reading ±2mA ensures precise measurement at 25°C
• Frequency response DC-100kHz enables high-frequency waveform capture
• 2m cable and safety BNC connector allow secure oscilloscope connections

Applications


• Suitable for waveform capture with oscilloscopes and recorders
• Used for troubleshooting DC motor and drive current anomalies
• Ideal for verifying control circuit currents up to 30A
• Can be used for high-frequency signal monitoring in power electronics
• Used with test instruments requiring voltage-output current probes

What power source does it require and how long does it last?


It uses a 9V alkaline IEC6LR61 battery and provides approximately 30 hours of operation with a low-battery indicator.

What conductor size will it accept?


The clamp opens to accommodate conductors up to 19mm diameter.

Which safety and electromagnetic standards apply to its use?


It meets IEC 61326-1 for EMC and is rated to CAT III 300V for working voltage limits.

How is output zero adjusted for baseline correction?


A manual thumbwheel on the body allows the user to zero the output prior to measurement.

What loading conditions should the measuring instrument present?


The output expects a load impedance greater than 100kΩ and less than or equal to 100pF.

Warning

Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz.

Supplied with

Alkaline PP3 battery, 4mm shrouded plug adaptor and operator’s manual.