ABB GJL131 Contactor, 110V, 127 V Coil, 3-Pole, 12 A, 5.5 kW 127V, 4 NO, 690V
- RS stock no.:
- 253-4828
- Mfr. Part No.:
- GJL1311919R8104
- Manufacturer:
- ABB
Subtotal (1 pack of 5 units)*
R 10 673,42
(exc. VAT)
R 12 274,435
(inc. VAT)
FREE delivery for orders over R 1,500.00
Stocked by manufacturer
- Ready to ship from 18 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit | Per Pack* |
|---|---|---|
| 5 + | R 2,134.684 | R 10,673.42 |
*price indicative
- RS stock no.:
- 253-4828
- Mfr. Part No.:
- GJL1311919R8104
- Manufacturer:
- ABB
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 110, 127V | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 12A | |
| Power Rating | 5.5kW | |
| Series | GJL131 | |
| Function | Reversing Contactor | |
| Mount Type | DIN Rail | |
| Normal State Configuration | 4 NO | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Solder | |
| Minimum Operating Temperature | -20°C | |
| Operational Current Ie | 12A | |
| Contactor Application | Control Unit | |
| Control Circuit Voltage Uc | 127V | |
| Maximum Operating Temperature | 55°C | |
| Width | 58mm | |
| Depth | 47.7mm | |
| Standards/Approvals | UL60947 | |
| Length | 47.7mm | |
| Pole and Throw Configuration | 3 | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Contactor | ||
Coil Voltage 110, 127V | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 12A | ||
Power Rating 5.5kW | ||
Series GJL131 | ||
Function Reversing Contactor | ||
Mount Type DIN Rail | ||
Normal State Configuration 4 NO | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Solder | ||
Minimum Operating Temperature -20°C | ||
Operational Current Ie 12A | ||
Contactor Application Control Unit | ||
Control Circuit Voltage Uc 127V | ||
Maximum Operating Temperature 55°C | ||
Width 58mm | ||
Depth 47.7mm | ||
Standards/Approvals UL60947 | ||
Length 47.7mm | ||
Pole and Throw Configuration 3 | ||
- COO (Country of Origin):
- DE
ABB GJL131 Series Contactor, 12A Operational Current, 690V Contact Voltage - GJL1311919R8104
This contractor is a three-pole switching device designed for commercial control circuits where reversing of motor direction or load switching is required. It operates on a control Coil rated for common supply levels and provides multiple main contacts for switching alternating current up to a defined operational current. The unit is intended for DIN-rail mounting in electrical panels and conforms to recognised industrial electrical standards.
Features and Benefits:
• 12A operational current delivers predictable switching capacity
• 690V contact rating supports high-voltage AC systems
• Reversing configuration allows bidirectional motor control
• 1NO auxiliary contact enables simple signalling and interlock use
• Solder pin terminals facilitate PCB or Compact wiring installations
• UL60947 approval simplifies integration into compliant assemblies
• 690V contact rating supports high-voltage AC systems
• Reversing configuration allows bidirectional motor control
• 1NO auxiliary contact enables simple signalling and interlock use
• Solder pin terminals facilitate PCB or Compact wiring installations
• UL60947 approval simplifies integration into compliant assemblies
Applications
• Suitable for reversing three-phase motor starters in factories
• Ideal for commercial equipment control panels with limited space
• Used for load switching in AC distribution and motor control centres
• Can be used for signalling to PLCs and auxiliary control circuits
• Ideal for commercial equipment control panels with limited space
• Used for load switching in AC distribution and motor control centres
• Can be used for signalling to PLCs and auxiliary control circuits
Which Coil voltages will energise the control circuit?
The control Coil accepts either 110V or 127V AC supplies for activation of the contactor.
How many main switching poles are available and what is their layout?
It provides three main switching poles in a 3P arrangement for three-phase circuits.
What ambient temperatures can the device tolerate in service?
The unit is rated to operate reliably between -20°C and 55°C ambient conditions.
What power can it handle for typical motor loads?
The device is specified with a power rating of 5.5kW, suitable for modest commercial motors.
How Compact is the unit for panel design considerations?
The contactor has a narrow footprint with an overall width of 96.2mm for space-conscious installations.
Related links
- ABB GJL131 Contactor 3-Pole 5.5 kW 127 V 690V
- ABB GJL131 Contactor 4-Pole 4 NO, 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 110 to 127 V ac 690V
- ABB GJL131 Contactor 4-Pole 5.5 kW 110 to 127 V ac 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 110 to 125 V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 125 V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 110 to 127 V ac 690V
- Siemens 3RT1 Contactor 3-Pole 200 kW 127 V 1kV