ABB GJL131 Contactor, 220V, 240 V Coil, 3-Pole, 20 A, 5.5 kW 240V, 3 NO/1 NC, 250 V dc, 690V ac
- RS stock no.:
- 253-4825
- Mfr. Part No.:
- GJL1311911R8010
- Manufacturer:
- ABB
Subtotal (1 unit)*
R 2 257,60
(exc. VAT)
R 2 596,24
(inc. VAT)
FREE delivery for orders over R 1,500.00
Stocked by manufacturer
- Ready to ship from 11 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | R 2,257.60 |
*price indicative
- RS stock no.:
- 253-4825
- Mfr. Part No.:
- GJL1311911R8010
- Manufacturer:
- ABB
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Coil Voltage | 220, 240V | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 250, 690V dc | |
| Contact Current | 20A | |
| Power Rating | 5.5kW | |
| Series | GJL131 | |
| Mount Type | DIN Rail | |
| Function | Motor Control | |
| Normal State Configuration | 3 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Screw | |
| Contactor Application | Control Unit | |
| Control Circuit Voltage Uc | 240V | |
| Operational Current Ie | 20A | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 55°C | |
| Standards/Approvals | IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | |
| Depth | 46.7mm | |
| Length | 46.7mm | |
| Width | 58mm | |
| Pole and Throw Configuration | 3P | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Coil Voltage 220, 240V | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 250, 690V dc | ||
Contact Current 20A | ||
Power Rating 5.5kW | ||
Series GJL131 | ||
Mount Type DIN Rail | ||
Function Motor Control | ||
Normal State Configuration 3 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Screw | ||
Contactor Application Control Unit | ||
Control Circuit Voltage Uc 240V | ||
Operational Current Ie 20A | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 55°C | ||
Standards/Approvals IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | ||
Depth 46.7mm | ||
Length 46.7mm | ||
Width 58mm | ||
Pole and Throw Configuration 3P | ||
- COO (Country of Origin):
- DE
ABB GJL131 Series Contactor, 20A Operational Current, 220V Control Circuit Voltage - GJL1311911R8010
This contactor is a three-pole device designed to control three-phase motor loads in industrial control circuits. It operates from low-voltage control supplies and is intended for installation in electrical distribution and control panels where Compact switching of motors up to several kilowatts is required.
Features and Benefits:
• 20A rated current for handling moderate motor loads
• Accepts 220V or 240V control coils for flexible supply options
• Switches up to AC690V and DC250V for mixed-voltage systems
• 3NO1NC auxiliary arrangement for additional control signalling
• Screw terminals for secure conductor connections
• DIN rail or wall mounting for straightforward panel integration
• Accepts 220V or 240V control coils for flexible supply options
• Switches up to AC690V and DC250V for mixed-voltage systems
• 3NO1NC auxiliary arrangement for additional control signalling
• Screw terminals for secure conductor connections
• DIN rail or wall mounting for straightforward panel integration
Applications
• Suitable for direct control of 5.5kW three-phase motors
• Ideal for motor starters in factory automation panels
• Used with contactor-based motor protection and interlocking schemes
• Can be used for switching heavy AC or DC control loads in machinery
• Ideal for motor starters in factory automation panels
• Used with contactor-based motor protection and interlocking schemes
• Can be used for switching heavy AC or DC control loads in machinery
What ambient temperature range can it operate within?
It is specified to function between -20°C and 55°C, enabling use in typical industrial environments.
How many power poles does it include and what is the switching configuration?
The device contains three power poles configured as a 3P contact arrangement for three-phase switching.
What mounting options are available for installation flexibility?
It supports both DIN rail mounting and direct wall mounting to suit different enclosure layouts.
Which standards govern its electrical design and testing?
It is designed to meet international IEC/EN requirements for low-voltage switching and associated device standards.
How is the control circuit voltage denoted for selection?
The control circuit accepts nominal voltages of 220 and 240V for Coil operation.
Related links
- ABB GJL131 Contactor 4-Pole 5.5 kW 240 V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 240 V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 240 V dc 690V
- ABB GJL131 Contactor 4-Pole 5.5 kW 240 V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 220 to 240 V 690V dc
- ABB GJL131 Contactor 3-Pole 5.5 kW 220 to 240 V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 24 V ac 250 V dc, 690V ac
- ABB GJL131 Contactor 4-Pole 5.5 kW 220 to 240 V 690V