ABB GJL131 Contactor, 42V Coil, 3-Pole, 20 A, 5.5 kW 42V, 3 NO/1 NC, 690V
- RS stock no.:
- 253-4794
- Mfr. Part No.:
- GJL1311001R0012
- Manufacturer:
- ABB
Temporarily out of stock
- RS stock no.:
- 253-4794
- Mfr. Part No.:
- GJL1311001R0012
- Manufacturer:
- ABB
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Coil Voltage | 42V | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Series | GJL131 | |
| Power Rating | 5.5kW | |
| Mount Type | DIN Rail | |
| Function | Mini Contactor | |
| Normal State Configuration | 3 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Auxiliary Contact Configuration | 1 NO/0 NC | |
| Terminal Type | Screw | |
| Contactor Application | Control Unit | |
| Control Circuit Voltage Uc | 42V | |
| Operational Current Ie | 20A | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 55°C | |
| Standards/Approvals | IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | |
| Length | 46.7mm | |
| Depth | 46.7mm | |
| Width | 53mm | |
| Pole and Throw Configuration | 3 | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Coil Voltage 42V | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Series GJL131 | ||
Power Rating 5.5kW | ||
Mount Type DIN Rail | ||
Function Mini Contactor | ||
Normal State Configuration 3 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Auxiliary Contact Configuration 1 NO/0 NC | ||
Terminal Type Screw | ||
Contactor Application Control Unit | ||
Control Circuit Voltage Uc 42V | ||
Operational Current Ie 20A | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 55°C | ||
Standards/Approvals IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | ||
Length 46.7mm | ||
Depth 46.7mm | ||
Width 53mm | ||
Pole and Throw Configuration 3 | ||
- COO (Country of Origin):
- DE
ABB GJL131 Series Contactor, 20A Operational Current, 690V Contact Voltage - GJL1311001R0012
This contactor is a Compact switching device designed for commercial electrical control tasks, providing three-pole power interruption for motors and circuits within automated and industrial installations. It is intended for use where a Compact footprint and straightforward mounting are required, accommodating both DIN-rail and wall installations and operating within typical commercial temperature ranges.
Features and Benefits:
• 3P configuration delivers controlled switching across three phases
• 20 A operational current supports moderate motor loads
• 42V control circuit enables low-voltage Coil operation
• 690V rated contacts permit high-voltage switching capability
• Screw terminals ensure secure conductor connections
• 5.5 kW power rating handles common commercial motor demands
• 20 A operational current supports moderate motor loads
• 42V control circuit enables low-voltage Coil operation
• 690V rated contacts permit high-voltage switching capability
• Screw terminals ensure secure conductor connections
• 5.5 kW power rating handles common commercial motor demands
Applications
• Suitable for control panels in light industrial automation
• Ideal for switching three-phase commercial motors
• Used with starter circuits in building services installations
• Can be used for remote power control in production lines
• Suitable for retrofit projects requiring small-footprint contactors
• Ideal for switching three-phase commercial motors
• Used with starter circuits in building services installations
• Can be used for remote power control in production lines
• Suitable for retrofit projects requiring small-footprint contactors
What auxiliary contact arrangement is available for signalling or interlock functions?
It provides a single auxiliary contact arranged as zero normally open and one normally closed to support Basic signalling and safety interlocks.
How does ambient temperature affect operational reliability?
It is specified to function across a working range from −25 °C up to 55 °C, accommodating colder and warmer commercial environments without derating.
Which mounting options are supported for installation flexibility?
You can fit it to standard DIN-rail systems or attach it directly to a wall to suit panel layouts and space constraints.
What standards does the device meet for compatibility with industrial control systems?
It conforms to relevant IEC/EN and UL standards for low-voltage switchgear, ensuring consistent interfacing with other certified control equipment.
Related links
- ABB GJL131 Contactor 4-Pole 5.5 kW 42 V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 42 V 250 V dc, 690V ac
- ABB GJL131 Contactor 4-Pole 5.5 kW 42 V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 415 V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 48 V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 127 V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 12 V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 24 V 690V