ABB GJL121 Contactor, 110V, 125 V Coil, 3-Pole, 20 A, 4 kW 125V, 3 NO/1 NC, 690V
- RS stock no.:
- 253-4784
- Mfr. Part No.:
- GJL1213901R0014
- Manufacturer:
- ABB
Subtotal (1 unit)*
R 1 734,02
(exc. VAT)
R 1 994,12
(inc. VAT)
FREE delivery for orders over R 1,500.00
Stocked by manufacturer
- Ready to ship from 18 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | R 1,734.02 |
*price indicative
- RS stock no.:
- 253-4784
- Mfr. Part No.:
- GJL1213901R0014
- Manufacturer:
- ABB
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 110, 125V | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Series | GJL121 | |
| Power Rating | 4kW | |
| Mount Type | DIN Rail | |
| Function | Reversing Contactor | |
| Normal State Configuration | 3 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Screw | |
| Operational Current Ie | 20A | |
| Control Circuit Voltage Uc | 125V | |
| Contactor Application | Control Unit | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 55°C | |
| Depth | 46.7mm | |
| Width | 58mm | |
| Length | 46.7mm | |
| Standards/Approvals | IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC/EN 60947-1, IEC/EN 60947-4-1 | |
| Pole and Throw Configuration | 3 | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Contactor | ||
Coil Voltage 110, 125V | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Series GJL121 | ||
Power Rating 4kW | ||
Mount Type DIN Rail | ||
Function Reversing Contactor | ||
Normal State Configuration 3 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Screw | ||
Operational Current Ie 20A | ||
Control Circuit Voltage Uc 125V | ||
Contactor Application Control Unit | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 55°C | ||
Depth 46.7mm | ||
Width 58mm | ||
Length 46.7mm | ||
Standards/Approvals IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC/EN 60947-1, IEC/EN 60947-4-1 | ||
Pole and Throw Configuration 3 | ||
- COO (Country of Origin):
- DE
ABB GJL121 Series Contactor, 20A Operational Current, 690V Contact Voltage - GJL1213901R0014
This contactor is a three-pole switching device designed for commercial and industrial control circuits, providing reversing functionality for motor and load control. It operates with a control Coil supplied at either 110V or 125V and is specified for switching currents up to 20 A and voltages up to 690 V, making it suitable for medium-power electrical systems.
Features and Benefits:
• 3P configuration enables three-phase reversing control
• 20 A operational current supports 4 kW power loads
• 110V or 125V Coil voltages allow flexible control integration
• 3NO1NC auxiliary contact provides monitoring and interlock capability
• Screw terminals ensure secure electrical connections
• DIN-rail and wall mounting offer versatile installation options
• 20 A operational current supports 4 kW power loads
• 110V or 125V Coil voltages allow flexible control integration
• 3NO1NC auxiliary contact provides monitoring and interlock capability
• Screw terminals ensure secure electrical connections
• DIN-rail and wall mounting offer versatile installation options
Applications
• Suitable for reversing three-phase motor starters in factories
• Ideal for control panels requiring auxiliary feedback contacts
• Used with 4 kW industrial drives and small motor
• Can be used in building services distribution and switching racks
• Suitable for automation systems requiring IEC 60947-compliant contactors
• Ideal for control panels requiring auxiliary feedback contacts
• Used with 4 kW industrial drives and small motor
• Can be used in building services distribution and switching racks
• Suitable for automation systems requiring IEC 60947-compliant contactors
What environmental temperature range can it tolerate?
It is rated to operate between -20 °C and 55 °C, covering typical indoor industrial environments.
How many auxiliary contacts are provided and what is their configuration?
A single auxiliary contact is fitted, arranged as one normally closed contact alongside the main poles.
What mounting methods are supported for panel integration?
It can be mounted on a DIN rail or attached directly to a wall, enabling flexible panel layout.
Which standards and approvals does it conform to for electrical switchgear?
It meets IEC/EN 60947-1 and IEC/EN 60947-4-1 standards and carries related UL listings.
Related links
- ABB GJL121 Contactor 3-Pole 4 kW 125 V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 110 to 125 V 690V dc
- ABB GJL121 Contactor 4-Pole 2.2 kW 110 to 125 V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 110 to 125 V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 110 to 127 V ac 690V
- ABB GJL121 Contactor 4-Pole 4 kW 127 V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 110 to 127 V ac 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 125 V 690V