ABB GJL121 Contactor, 24V Coil, 3-Pole, 12 A, 4 kW 24V, 4 NO, 690V
- RS stock no.:
- 253-4772
- Mfr. Part No.:
- GJL1213009R0101
- Manufacturer:
- ABB
Image representative of range
Subtotal (1 pack of 10 units)*
R 6 920,95
(exc. VAT)
R 7 959,09
(inc. VAT)
FREE delivery for orders over R 1,500.00
Stocked by manufacturer
- Ready to ship from 02 June 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit | Per Pack* |
|---|---|---|
| 10 + | R 692.095 | R 6,920.95 |
*price indicative
- RS stock no.:
- 253-4772
- Mfr. Part No.:
- GJL1213009R0101
- Manufacturer:
- ABB
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Coil Voltage | 24V | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 12A | |
| Power Rating | 4kW | |
| Series | GJL121 | |
| Function | Mini Contactor | |
| Mount Type | DIN Rail | |
| Normal State Configuration | 4 NO | |
| Auxiliary Contact Configuration | 1 NO/0 NC | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Solder Pin | |
| Minimum Operating Temperature | -25°C | |
| Operational Current Ie | 12A | |
| Contactor Application | Control Unit | |
| Control Circuit Voltage Uc | 24V | |
| Maximum Operating Temperature | 55°C | |
| Length | 47.7mm | |
| Depth | 47.7mm | |
| Width | 46mm | |
| Standards/Approvals | IEC/EN 60947-5-1, UL 60947-4-1, UL 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-1 | |
| Pole and Throw Configuration | 3P | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Coil Voltage 24V | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 12A | ||
Power Rating 4kW | ||
Series GJL121 | ||
Function Mini Contactor | ||
Mount Type DIN Rail | ||
Normal State Configuration 4 NO | ||
Auxiliary Contact Configuration 1 NO/0 NC | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Solder Pin | ||
Minimum Operating Temperature -25°C | ||
Operational Current Ie 12A | ||
Contactor Application Control Unit | ||
Control Circuit Voltage Uc 24V | ||
Maximum Operating Temperature 55°C | ||
Length 47.7mm | ||
Depth 47.7mm | ||
Width 46mm | ||
Standards/Approvals IEC/EN 60947-5-1, UL 60947-4-1, UL 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-1 | ||
Pole and Throw Configuration 3P | ||
- COO (Country of Origin):
- DE
ABB GJL121 Series Contactor, 12A Operational Current, 24V Control Circuit Voltage Uc - GJL1213009R0101
This contactor provides Compact switching for commercial control circuits, designed to manage three-phase loads in automation and electrical installations. It operates with a low-voltage control circuit and is intended for DIN-rail mounting in panel environments where space efficiency and straightforward integration are required.
Features and Benefits:
• 24V Coil enables integration with common control systems
• 3P configuration delivers three-pole switching for three-phase loads
• 12A operational current supports moderate motor and load duty
• 4kW power rating handles small motor and heater circuits
• 690V contact voltage permits use on high-voltage distribution systems
• 1NO auxiliary contact offers simple signalling or interlocking
• 3P configuration delivers three-pole switching for three-phase loads
• 12A operational current supports moderate motor and load duty
• 4kW power rating handles small motor and heater circuits
• 690V contact voltage permits use on high-voltage distribution systems
• 1NO auxiliary contact offers simple signalling or interlocking
Applications
• Suitable for small motor starters in factory automation
• Ideal for control panels in commercial electrical installations
• Used with PLC-driven control schemes requiring low-voltage coils
• Can be used for switching resistive heater loads up to rated power
• Ideal for control panels in commercial electrical installations
• Used with PLC-driven control schemes requiring low-voltage coils
• Can be used for switching resistive heater loads up to rated power
What mounting method does it require?
It clips onto a DIN rail for secure panel installation and easy replacement.
How does the contact arrangement support control logic?
The main switching is three-pole while a single normally open auxiliary contact provides a Basic status or interlock signal to external circuits.
What Terminal format should installers expect?
Connections are via solder pin terminals suitable for PCB or specific wiring adaptors.
What environmental limits apply to operation?
It is rated to operate down to -25°C and up to 55°C ambient temperature.
How many auxiliary contacts are fitted?
A single auxiliary contact is provided for signalling or control feedback.
Related links
- ABB GJL121 Contactor 3-Pole 4 kW 24 V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 24 V 690V
- ABB GJL121 Contactor 3-Pole 4 NO, 690V
- ABB GJL121 Contactor 3-Pole 1.4 kW 24 V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 24 V ac 690V
- ABB GJL121 Contactor 3-Pole 4 kW 24 V ac 690V
- ABB GJL121 Contactor 3-Pole 3 NO 690V ac
- ABB GJL121 Contactor 3-Pole 4 kW 24 V 690V