Hook Up Wire | Flexible wiring | PVC cable | RS
Login / Register to access your benefits
Recently searched

    Hook Up Wire

    Hook-up wire is a term commonly used in electronics and electrical engineering to refer to insulated electrical wires that are used for various electrical connections. These wires typically have a solid or stranded core made of materials like copper or aluminum and are covered with a protective insulating material, such as PVC (polyvinyl chloride) or Teflon (PTFE). The insulation is colour-coded to indicate the wire's purpose and to help with proper identification in electrical circuits.

    Hook-up wire is available in various gauges (wire diameters) to suit different applications, and it comes in different colours to facilitate organization and identification within electrical circuits. The colour coding often follows industry standards or specific conventions, such as red for positive (+) connections and black for negative (-) connections in direct current (DC) circuits.

    When working on electrical or electronics projects, it's important to choose the appropriate gauge and type of hook-up wire for your specific application to ensure safety and proper functioning of the circuit.

    What are the types of hook up wire?

    Here are some common types of hook-up wire:

    1. Single Conductor Wire: This is the most basic type of hook-up wire, consisting of a single insulated conductor. It's suitable for general-purpose use and available in various gauges and insulation materials.
    2. Stranded Wire: Stranded hook-up wire is made up of multiple smaller strands of wire twisted together. This construction makes it more flexible and suitable for applications where the wire may need to bend or flex.
    3. Solid Wire: Solid hook-up wire consists of a single, solid conductor. It's less flexible than stranded wire but is preferred in situations where minimal signal loss or resistance is crucial, such as in high-frequency applications.
    4. Shielded Wire: This type of wire has an additional layer of shielding, typically made of metal, around the insulated conductor. Shielded wire is used to protect against electromagnetic interference (EMI) and radio frequency interference (RFI). It's commonly used in audio and communication applications.
    5. High-Temperature Wire: For applications where extreme heat resistance is required, high-temperature hook-up wire is used. These wires are designed to withstand temperatures significantly higher than standard wire.
    6. Multi-Conductor Cable: While not technically a type of hook-up wire, multi-conductor cables consist of multiple insulated conductors bundled together within a single cable.
    7. Specialty Wire: Some applications require specialty hook-up wire, such as magnet wire (enamel-coated wire used in electromagnets and transformers) or automotive-grade wire (designed for use in vehicles).
    8. Harsh Environment Wire: refers to electrical wiring and cables designed specifically for use in extreme or challenging environmental conditions. These conditions can include exposure to high temperatures, moisture, chemicals, physical abrasion, and other harsh factors that standard wires may not withstand.

    Typical Applications

    These wires are used in a wide range of applications, from simple breadboard prototypes to complex electronic devices.

    • Internal Wiring of Appliances
    • Automotive Applications
    • Robotics and Automation
    • Aerospace
    • Medical

    7079 Products showing for Hook Up Wire

    RS PRO
    Tri-rated
    25mm²
    Black
    4 AWG
    Single Core
    196/0.4 mm
    PVC
    100m
    10.6mm
    -
    721
    600 V
    -
    +105°C
    -15°C
    136 A
    Annealed Copper
    0.4mm
    -
    CSA C22.2 Type TEW, UK BS 6231, UL 1283
    -
    -
    -
    -
    -
    -
    -
    1.58mm
    Unshielded
    RS PRO
    -
    25mm²
    Green/Yellow
    -
    Single Core
    7/2.14 mm
    LSNH EI5
    100m
    10.1mm
    H07V-R
    7
    450 V dc, 750 V ac
    Dca
    90°C
    -15°C
    -
    Copper
    2.14mm
    Conduit
    BS EN 50525-3-41:2011 Clause 4.1
    -
    -
    6491B
    -
    -
    H07Z-R
    -
    1.2mm
    -
    RS PRO
    Tri-rated
    25mm²
    Green/Yellow
    4 AWG
    Single Core
    196/0.4 mm
    PVC
    100m
    10.6mm
    H07V2-K
    196
    600 V
    -
    +105°C
    -15°C
    136 A
    Annealed Copper
    0.4mm
    -
    CSA C22.2 Type TEW, UK BS 6231, UL 1283
    -
    -
    -
    -
    -
    H07V2-K
    -
    1.6mm
    Unshielded
    RS PRO
    -
    35mm²
    Green/Yellow
    -
    Single Core
    7/2.52 mm
    LSNH EI5
    50m
    11.3mm
    H07Z-R
    7
    450 V dc, 750 V ac
    Dca
    90°C
    -15°C
    -
    Copper
    2.52mm
    Conduit
    BS EN 50525-3-41:2011 Clause 4.1
    -
    -
    6491B
    -
    -
    H07Z-R
    -
    1.2mm
    -
    RS PRO
    -
    25mm²
    Black
    3 AWG
    Round
    234/0.35 mm
    PVC
    100m
    12.7 → 15.8mm
    H07BN4-F
    234
    750 V
    -
    +90°C
    -40°C
    -
    Copper
    0.35mm
    -
    Euroclass Eca
    -
    Flame Retardant
    -
    -
    -
    H07BN4-F
    -
    -
    -
    RS PRO
    -
    35mm²
    Black
    -
    Single Core
    7/2.52 mm
    PVC TI1
    50m
    10.9mm
    H07V-R
    7
    450 V dc, 750 V ac
    Eca
    70°C
    -15°C
    -
    Copper
    2.52mm
    Conduit
    BS EN 50525-2-31:2011 Clause 4.1
    -
    -
    6491X
    -
    -
    H07V-R
    -
    1.2mm
    -
    RS PRO
    -
    35mm²
    Brown
    -
    Single Core
    7/2.52 mm
    LSNH EI5
    50m
    11.3mm
    H07Z-R
    7
    450 V dc, 750 V ac
    Dca
    90°C
    -15°C
    -
    Copper
    2.52mm
    Conduit
    BS EN 50525-3-41:2011 Clause 4.1
    -
    -
    6491B
    -
    -
    H07Z-R
    -
    1.2mm
    -
    RS PRO
    Tri-rated
    25mm²
    Red
    4 AWG
    Single Core
    196/0.4 mm
    PVC
    100m
    10.6mm
    H07V2-K
    196
    600 V
    -
    +105°C
    -15°C
    136 A
    Annealed Copper
    0.4mm
    -
    CSA C22.2 Type TEW, UK BS 6231, UL 1283
    -
    -
    -
    -
    -
    H07V2-K
    -
    1.6mm
    Unshielded
    RS PRO
    -
    16mm²
    Black
    -
    Single Core
    7/1.7 mm
    LSNH EI5
    100m
    8mm
    H07V-R
    7
    450 V dc, 750 V ac
    Dca
    90°C
    -15°C
    -
    Copper
    1.7mm
    Conduit
    BS EN 50525-3-41:2011 Clause 4.1
    -
    -
    6491B
    -
    -
    H07Z-R
    -
    1mm
    -
    RS PRO
    Tri-rated
    16mm²
    Black
    6 AWG
    Single Core
    126/0.4 mm
    PVC
    100m
    9.2mm
    -
    126
    600 V
    -
    +105°C
    -15°C
    100 A
    Annealed Copper
    0.4mm
    -
    CSA C22.2 Type TEW, UK BS 6231, UL 1283
    -
    -
    -
    -
    -
    -
    -
    1.58mm
    Unshielded
    RS PRO
    -
    25mm²
    Grey
    -
    Single Core
    7/2.14 mm
    PVC TI1
    50m
    9.7mm
    H07V-R
    7
    450 V dc, 750 V ac
    Eca
    70°C
    -15°C
    -
    Copper
    2.14mm
    Conduit
    BS EN 50525-2-31:2011 Clause 4.1
    -
    -
    6491X
    -
    -
    H07V-R
    -
    1.2mm
    -
    RS PRO
    -
    10mm²
    Green/Yellow
    -
    Single Core
    7/1.35 mm
    LSNH EI5
    100m
    7mm
    H07V-U
    7
    450 V dc, 750 V ac
    Dca
    90°C
    -15°C
    -
    Copper
    1.35mm
    Conduit
    BS EN 50525-3-41:2011 Clause 4.1
    -
    -
    6491B
    -
    -
    H07Z-R
    -
    1mm
    -
    RS PRO
    -
    2.1mm²
    Black
    14 AWG
    -
    1C
    MPPE
    305m
    -
    -
    -
    600 V
    -
    -
    -
    -
    -
    mm
    -
    -
    -
    -
    11028
    -
    -
    -
    -
    -
    -
    RS PRO
    -
    1.32mm²
    Black
    16 AWG
    -
    1C
    PVC
    305m
    -
    -
    -
    300 V
    -
    -
    -
    -
    -
    mm
    -
    -
    -
    -
    1569
    -
    -
    -
    -
    -
    -
    RS PRO
    -
    0.5mm²
    Black
    20 AWG
    Single Core
    16/0.2 mm
    PVC
    100m
    1.65mm
    -
    16
    1 kV ac
    -
    +85°C
    -15°C
    -
    Annealed Tinned Copper
    mm
    Single Core
    Def Stan 61-12 Part 6
    BS4808
    -
    -
    -
    -
    -
    -
    0.3mm
    Unshielded
    RS PRO
    Tri-rated
    10mm²
    Green/Yellow
    8 AWG
    Single Core
    72/0.4 mm
    PVC
    100m
    6.8mm
    H07V2-K
    72
    600 V
    -
    +105°C
    -15°C
    75 A
    Annealed Copper
    0.4mm
    -
    CSA C22.2 Type TEW, UK BS 6231, UL 1028
    -
    -
    -
    -
    -
    H07V2-K
    -
    1.2mm
    Unshielded
    RS PRO
    -
    16mm²
    Red
    5 AWG
    Single Core
    126/0.4 mm
    PVC
    25m
    9mm
    -
    126
    600 V
    -
    +70°C
    -15°C
    95 A
    Annealed Copper
    0.4mm
    Control
    BS 6231
    -
    -
    FLEXIBLE BK
    -
    -
    -
    -
    1mm
    Unshielded
    RS PRO
    Tri-rated
    4mm²
    Black
    12 AWG
    Single Core
    52/0.3 mm
    PVC
    100m
    4.3mm
    H07V2-K
    52
    1 kV
    -
    +105 (Air), +60 (Oil)°C
    -15°C
    41 A
    Annealed Copper
    0.3mm
    -
    CSA C22.2 Type TEW, UK BS 6231, UL 1015
    -
    -
    -
    -
    -
    H07V2-K
    -
    0.8mm
    Unshielded
    RS PRO
    -
    0.05mm²
    Black
    30 AWG
    Single Core
    1/0.25 mm
    Tefzel
    100m
    0.56mm
    -
    1
    375 V
    -
    +150°C
    -90°C
    -
    Tinned Copper
    0.25mm
    -
    RoHS Compliant
    -
    -
    -
    -
    -
    -
    -
    0.5mm
    -
    RS PRO
    -
    10mm²
    Black
    -
    Single Core
    7/1.35 mm
    LSNH EI5
    50m
    7mm
    H07V-R
    7
    450 V dc, 750 V ac
    Dca
    90°C
    -15°C
    -
    Copper
    1.35mm
    Conduit
    BS EN 50525-3-41:2011 Clause 4.1
    -
    -
    6491B
    -
    -
    H07Z-R
    -
    1mm
    -
    Results per page