Keithley 2700/E Bench Front Panel Digital Multimeter, True RMS, 3A ac Max, 3A dc Max, 750V ac Max
- RS stock no.:
- 760-0357
- Mfr. Part No.:
- 2700/E
- Manufacturer:
- Keithley
Discontinued product
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
R 48 146,40
(exc. VAT)
R 55 368,36
(inc. VAT)
- RS stock no.:
- 760-0357
- Mfr. Part No.:
- 2700/E
- Manufacturer:
- Keithley
Exempt
- COO (Country of Origin):
- CN
Keithley 2700, 2701, 2750 Multimeter/Data Acquisition/Switch Systems
Keithley's Integra series systems 2700, 2701 and 2750 combine precision measurement, switching and control in a single, tightly integrated enclosure for either rack-mounted or benchtop applications. Built-in measurement functions include: DCV, ACV, DCI, ACI; Resistance, 2- or 4-wire, offset compensation selectable; Temperature (with thermocouples, RTDs or thermistors; Frequency/Period; Continuity.
Models include:
Similar Features and Benefits:
Cost effective - Combines functions of digital multimeter, switch system and datalogger
True 6-digit (22 bit) resolution
Can select 12 switch/control plug-in modules
Up to 200 differential input channels (with 300 V isolation) for measurement and control
Convenient front panel inputs
ExceLINX - 1A datalogging software
True 6-digit (22 bit) resolution
Can select 12 switch/control plug-in modules
Up to 200 differential input channels (with 300 V isolation) for measurement and control
Convenient front panel inputs
ExceLINX - 1A datalogging software
Setup and Operation
These Integra systems are fully integrated measurement and control systems and are fast and easy to set up and start working within minutes of installation.
Advantages of Integrated Design
Due to their flexible modular architecture and integrated measurement, switching, and control capabilities save rack space by reducing the number of separate instruments needed.
As the number of channels grows, new test requirements evolve.
Integrated signal conditioning, scaling, stimulus, filtering and I/O capabilities eliminate the need for external circuitry when designing and building data acquisition systems.
Integra systems offer greater accuracy and repeatability to plug-in data acquisition boards, while providing faster test times than typical DMM/switch systems. This makes it possible to combine higher test yields with higher test throughput.
As the number of channels grows, new test requirements evolve.
Integrated signal conditioning, scaling, stimulus, filtering and I/O capabilities eliminate the need for external circuitry when designing and building data acquisition systems.
Integra systems offer greater accuracy and repeatability to plug-in data acquisition boards, while providing faster test times than typical DMM/switch systems. This makes it possible to combine higher test yields with higher test throughput.
Different features between the models: (Please see selector guide on page 5 of the datasheet for more information)
2701
Ethernet and RS-232 interfaces – offers an Ethernet connection for high-speed and long-distance communication between a computer and various instruments. Includes 2 slots for the plug-in modules.
2700
GPIB and RS-232 interfaces
2750
GPIB and RS-232 interfaces
Dry circuit ohms (20 mV clamp) - Protects sensitive devices from damage and prevents self-heating errors during testing.
Ethernet and RS-232 interfaces – offers an Ethernet connection for high-speed and long-distance communication between a computer and various instruments. Includes 2 slots for the plug-in modules.
2700
GPIB and RS-232 interfaces
2750
GPIB and RS-232 interfaces
Dry circuit ohms (20 mV clamp) - Protects sensitive devices from damage and prevents self-heating errors during testing.
Applications include:
Production test of electronic products and devices, accelerated stress testing (AST), process monitor and control, device characterisation/R&D and low ohms, multichannel measurements.
Note
Supplied with
LabVIEW, LabWindows/CVI, Visual Basic and C/C++ drivers (IVI style) software, manual, safety test leads
Keithley
Attribute | Value |
---|---|
Multimeter Type | Bench |
Model Number p | 2700/E |
Display Type | Front Panel |
Functions Measured | DC Current, DC Voltage, Resistance, Temperature |
Absolute Maximum DC Voltage Measurement | 1000V dc |
Absolute Maximum DC Current Measurement | 3A dc |
Absolute Maximum AC Current Measurement | 3A ac |
Absolute Maximum AC Voltage Measurement | 750V ac |
Absolute Maximum Resistance Measurement | 100MΩ |
Absolute Maximum Temperature Measurement | +1820°C |
Maximum Frequency | 500kHz |
DC Current Measurement Resolution | 1µA dc |
Resistance Measurement Resolution | 1µΩ |
DC Voltage Measurement Resolution | 0.1µV dc |
Temperature Measurement Resolution | 0.001°C |
Dimensions | 89 x 213 x 370mm |
Best DC Voltage Accuracy | ±0.003% + 3.5 Digits |
Best DC Current Accuracy | ±0.05% + 8 Digits |
Weight | 6.5kg |
Best Resistance Measurement Accuracy | ±0.01% + 4 Digits |
Battery Type | Lithium Battery |
Best Temperature Measurement Accuracy | ±0.2 °C |