Fluke 125B ScopeMeter 120B Series, 40MHz Handheld Oscilloscope, 2 Analogue Channels
- RS stock no.:
- 919-5069
- Mfr. Part No.:
- FLUKE-125B/INT
- Manufacturer:
- Fluke
Subtotal (1 unit)*
R 67 824,18
(exc. VAT)
R 77 997,81
(inc. VAT)
FREE delivery for orders over R 1,500.00
Temporarily out of stock
- Shipping from 03 April 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | R 67,824.18 |
*price indicative
- RS stock no.:
- 919-5069
- Mfr. Part No.:
- FLUKE-125B/INT
- Manufacturer:
- Fluke
Specification
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Bandwidth | 40MHz | |
| Number of Analogue Channels | 2 | |
| Oscilloscope Type | Handheld | |
| Interface | CAN, RS232, RS422, RS485, USB | |
| Sample Rate Random | 400 Ksps | |
| Screen Size | 5.7in | |
| Series | 120B | |
| Record Length | 2M points/ch | |
| Minimum Time Base | 10ns | |
| Dimensions | 259 x 132 x 55mm | |
| Maximum Vertical Sensitivity | 200V/div | |
| Power Source | Battery | |
| Digital/Analogue | Digital | |
| Maximum Time Base | 500ns/div | |
| Safety Category | CAT III 750 V, CAT IV 600V | |
| Battery Life | 7 h | |
| Weight | 1.4kg | |
| Rise Time | <8.75ns | |
| Minimum Vertical Sensitivity | 5mV/div | |
| Battery Type | Li-ion | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Bandwidth 40MHz | ||
Number of Analogue Channels 2 | ||
Oscilloscope Type Handheld | ||
Interface CAN, RS232, RS422, RS485, USB | ||
Sample Rate Random 400 Ksps | ||
Screen Size 5.7in | ||
Series 120B | ||
Record Length 2M points/ch | ||
Minimum Time Base 10ns | ||
Dimensions 259 x 132 x 55mm | ||
Maximum Vertical Sensitivity 200V/div | ||
Power Source Battery | ||
Digital/Analogue Digital | ||
Maximum Time Base 500ns/div | ||
Safety Category CAT III 750 V, CAT IV 600V | ||
Battery Life 7 h | ||
Weight 1.4kg | ||
Rise Time <8.75ns | ||
Minimum Vertical Sensitivity 5mV/div | ||
Battery Type Li-ion | ||
Exempt
- COO (Country of Origin):
- RO
Fluke 120B Series Oscilloscope, 40 MHz Bandwidth, 400 Ksps Sample Rate - FLUKE-125B/INT
This handheld oscilloscope is Ideal for professionals in the automation, electronics, and mechanical sectors. Featuring a Compact design with dimensions of 259 x 132 x 55 mm, this 40MHz oscilloscope offers robust functionality in a portable package. With a weight of just 1.4kg, it is engineered for convenience and efficiency in fieldwork.
Features & Benefits
• Dual analogue channels enable comprehensive signal analysis
• High sensitivity from 5 mV/div to 200 V/div enhances measurement accuracy
• Connectivity options include USB for easy data transfer
• Sample rate of 400 Ksps supports Rapid signal capture
• Powered by a long-lasting Li-ion battery for extended use
• Record length of 2 M points/ch allows detailed waveform inspection
• High sensitivity from 5 mV/div to 200 V/div enhances measurement accuracy
• Connectivity options include USB for easy data transfer
• Sample rate of 400 Ksps supports Rapid signal capture
• Powered by a long-lasting Li-ion battery for extended use
• Record length of 2 M points/ch allows detailed waveform inspection
Applications
• Utilised for automotive diagnostics and troubleshooting electrical systems
• Ideal for monitoring signals in industrial automation setups
• Supports field testing in mechanical and electrical maintenance
• Suitable for educators demonstrating electronic principles in classrooms
• Ideal for monitoring signals in industrial automation setups
• Supports field testing in mechanical and electrical maintenance
• Suitable for educators demonstrating electronic principles in classrooms
What is the significance of the 40 MHz bandwidth?
The 40MHz bandwidth allows for the accurate measurement of a wide range of frequencies, making it suitable for various applications, from automotive diagnostics to industrial electronics.
How does the oscilloscope's battery life influence its usability?
With a battery life of 7 hours, it provides ample time for field tests without the need for constant recharging, allowing for uninterrupted workflow during critical tasks.
What interfaces are available for data connectivity?
It features multiple interfaces, including CAN, RS232, RS422, RS485, and USB, offering versatility in connecting to different devices and systems for data logging and analysis.
How does the minimum time base of 10 ns benefit users?
A minimum time base of 10 ns improves the capability to capture Rapid signal changes, ensuring accurate depiction of high-speed electrical phenomena.
What safety ratings does this oscilloscope hold?
It holds CAT IV 600V and CAT III 750V safety ratings, ensuring it is reliable for use in both low- and high-voltage environments without compromising user safety.
Related links
- Fluke 125B ScopeMeter 120B Series 2 Analogue Channels
- Fluke 125B/EU/S 120B Series 2 Analogue Channels
- Fluke 124B ScopeMeter 120B Series 2 Analogue Channels
- Fluke 124B/EU/S 120B Series 2 Analogue Channels
- Fluke 123B ScopeMeter 120B Series 2 Analogue Channels
- Fluke 120B Series 2
- Fluke 123B/EU/S 120B Series 2 Analogue Channels
- Fluke 190-062-III ScopeMeter III Series 2 Analogue Channels
