Contactor & Thermal Overload Relays | RS
Login / Register to access your benefits
Recently searched

    Contactor Overload Relays

    All electric motors have a lifespan, and to keep them running efficiently and safely they must be protected. One of the main causes of failure is electrical overload, sometimes called overcurrent. When a motor draws more current than it is designed to handle it causes the temperature to build-up resulting in overheating. This damages motor windings and coils. It is important to protect the motor and its circuit, and this is where the use of contactor overload relays can help.RS offer an extensive range of high-quality contactor overload relays from leading industry brands including Schneider Electric, Siemens, ABB, Eaton, Lovato, and Rockwell Automation.

    What is overload protection?

    Overload is where a motor draws a high current above its rated value for an extended amount of time. Overload causes overheating of the motor causing damage. To prevent this from happening devices such as contactor relays are specifically designed for industrial control motor protection. They are used with contactors as part of a motor starter or in a control panel or centre.

    What are the different types of contactor overload relays?

    The motor protection devices can be classified into two main types which are thermal types and electronic types.Thermal overload relaysUtilise a bi-metallic plate located near a heating element. When excessive current is passed through the heating element N/C (Normally Closed) contacts switch over and opens contacts. This interrupts power from flowing to the contactor's control circuit. Thermal overloads usually offer an adjustable current range as well as a manual or automatic reset option.Electronic RelaysElectronic overload relays don't have a bi-metallic mechanism, Instead, they work by using components such as temperature sensors to measure the load current. They are generally more accurate than thermal devices and they usually have a wider current range, a selectable trip class provides enhanced trip protection against single phasing against the motor.

    1297 Products showing for Contactor Overload Relays

    Omron
    1.2 → 1.8 A
    1.8 A
    -
    -
    -
    -
    -
    15 kW
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Siemens
    20 → 25 A
    25 A
    SIRIUS
    3P
    690 V ac
    SIRIUS 3RU2
    Direct Contactor
    11 kW
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    73mm
    87mm
    +70°C
    -40°C
    -
    -
    -
    -40 → +70 °C
    Siemens
    1.8 → 2.5 A
    2.5 A
    SIRIUS
    3P
    690 V ac
    SIRIUS 3RU2
    Direct Contactor
    1.5 kW
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    73mm
    87mm
    +70°C
    -40°C
    -
    -
    -
    -40 → +70 °C
    WEG
    1.8 A
    1.2 → 1.8 A
    -
    3P
    690 V ac
    RW27
    Direct Contactor
    0.9 → 1.7 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    83.7mm
    71.7mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    Siemens
    12.5 A
    3 A
    SIRIUS
    3P
    -
    SIRIUS 3RU2
    -
    7.5 kW
    1NC/1NO
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Eaton
    0.4 → 0.6 A
    600 mA
    -
    3P
    -
    -
    -
    -
    NO/NC
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Eaton
    0.24 → 0.4 A
    400 mA
    -
    SP
    -
    -
    -
    0.12 kW
    1NO + 1NC
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Schneider Electric
    4 → 6 A
    5 A
    TeSys
    -
    -
    -
    -
    -
    1 NO + 1 NC
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Green Premium
    -
    Schneider Electric
    38 A
    3 A
    TeSys
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    WEG
    12.5 A
    8 → 12.5 A
    -
    3P
    690 V ac
    RW17
    DIN Rail Mount
    0.9 → 1.4 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    82.5mm
    71.5mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    WEG
    6.3 A
    4 → 6.3 A
    -
    3P
    690 V ac
    RW17
    DIN Rail Mount
    0.9 → 1.4 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    82.5mm
    71.5mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    Schneider Electric
    -
    10 A
    TeSys
    -
    -
    -
    -
    -
    1 NO + 1 NC
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Green Premium
    -
    ABB
    0.17 → 0.23 A
    230 mA
    AF Range
    3P
    690 V ac/dc
    TF42
    Direct Contactor
    2 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    70.5mm
    88.3mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    Allen Bradley
    160 → 800 A
    800 A
    Bulletin
    3P
    -
    -
    -
    -
    1NC + 1NO
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Siemens
    1.6 → 16 A
    1 A
    3RR2
    SP
    -
    3RR
    Direct Contactor
    0.0025 kW
    1NO + 1NC
    Automatic, Manual
    Screw
    1
    45mm
    81mm
    79mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    Schneider Electric
    1.2 → 7 A
    7 A
    TeSys
    -
    690 V ac
    LR97 D
    Direct Contactor
    55 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    67.5mm
    64.5mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    Schneider Electric
    1.2 → 7 A
    7 A
    TeSys
    -
    690 V ac
    LR97 D
    Direct Contactor
    55 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    67.5mm
    64.5mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    Siemens
    6.3 A
    6.3 A
    SIRIUS
    -
    -
    SIRIUS 3RU2
    -
    2.2 kW, 3 kW, 4 kW
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Schneider Electric
    0.3 → 1.5 A
    1.5 A
    TeSys
    -
    690 V ac
    LR97 D
    Direct Contactor
    55 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    67.5mm
    64.5mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    Schneider Electric
    0.3 → 1.5 A
    1.5 A
    TeSys
    -
    690 V ac
    LR97 D
    Direct Contactor
    55 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    67.5mm
    64.5mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    Results per page