- RS stock no.:
- 220-5884
- Mfr. Part No.:
- KANE258
- Manufacturer:
- Kane
- RS stock no.:
- 220-5884
- Mfr. Part No.:
- KANE258
- Manufacturer:
- Kane
Technical data sheets
Legislation and Compliance
Exempt
Product Details
KANE258 - Flue Gas Analyser with direct CO, O2 & CO sensor over-range protection
Features and benefits
Entry level Flue Gas Analyser for domestic gas applications with easy to use rotary dial, 6 line display & USB charger
Purge pump protection prevents accidental damage to CO sensor. Hydrogen (H2) ready - up to 20% blend.
Applications: Install & Service domestic oil & gas appliances. Combustion performance checks. Combustion efficiency checks.
Measures: CO 0-2,000ppm. O2 0-21%. Differential temperature. Calculates: CO2 0-20%. CO/CO2 ratio. Excess air. Combustion efficiency.
Fuel Types: Natural Gas, LPG, Wood, pellets, Butane, Light oil, Propane.
Data hold, log & print with user details to optional printer. Produce test reports: Combustion & temperature. Wireless option - connect to KANE LIVE & GAS CHECKER Apps.
Purge pump protection prevents accidental damage to CO sensor. Hydrogen (H2) ready - up to 20% blend.
Applications: Install & Service domestic oil & gas appliances. Combustion performance checks. Combustion efficiency checks.
Measures: CO 0-2,000ppm. O2 0-21%. Differential temperature. Calculates: CO2 0-20%. CO/CO2 ratio. Excess air. Combustion efficiency.
Fuel Types: Natural Gas, LPG, Wood, pellets, Butane, Light oil, Propane.
Data hold, log & print with user details to optional printer. Produce test reports: Combustion & temperature. Wireless option - connect to KANE LIVE & GAS CHECKER Apps.
Standards Met
Independently tested by TUV SUD to EN50379. Use for BS7967 & TB 413.
Supplied with:
KANE258 analyser, probe, small carry bag, USB charger, quick reference guide, analyser calibration certificate
Specification
Attribute | Value |
---|---|
Gases Detected | Carbon Dioxide, Carbon Monoxide, Oxygen |
Best Carbon Monoxide Accuracy | 5% |
Carbon Monoxide Resolution | 1ppm |
Best Carbon Dioxide Accuracy | 0.3% |
Model Number p | KANE258 |